Planet Networking & Communication UPOE-2400G User Manual page 54

8/16/24-port ultra poe managed injector hub
Hide thumbs Also See for UPOE-2400G:
Table of Contents

Advertisement

The page includes the following fields:
Object
• Mode
• Remote PD IP Address
• Interval Time (10~300s)
• Retry Count (1~5)
• Action
• Reboot Time (30~180s)
Buttons
: Click to apply changes
: Refreshes the Web page and the current configuration if user doesn't save it.
User's Manual of UPOE-800G/UPOE-1600G/UPOE-2400G
Description
Allows user to enable or disable per port PD Alive Check function. All ports are
disabled as default value.
This column allows user to set PoE device IP address here for system making ping
to the PoE device. Please note that the PD's IP address must be set to the same
network segment as the Ultra PoE Managed Injector Hub.
This column allows user to set how long system should issue a ping request to PD
for detecting whether PD is alive or dead. Interval time range is from 10 seconds to
300 seconds.
This column allows user to set how many times system wants to retry ping to PD.
For example, if we set count 2, the meaning is that if system retry ping to the PD
and the PD doesn't response continuously, the PoE port will be reset.
Allows user to set which action will be apply if the PD is without any response. The
Ultra PoE Managed Injector Hub offers 3 actions as follows:
 PD Reboot: It means system will reset the PoE port that is connected to the
PD.
 PD Reboot & Alarm: It means system will reset the PoE port and issue an
alarm message via Syslog,
 Alarm: It means system will issue an alarm message via Syslog..
This column allows user to set the PoE device rebooting time. As there are so many
kinds of PoE devices on the market, they have different rebooting times.
The PD Alive-check is not a defining standard, so the PoE device on the market
doesn't report reboots done information to the Ultra PoE Managed Injector Hub. So
user has to make sure how long the PD will be finished to boot, and then set the
time value to this column.
System is going to check the PD again according to the reboot time. If you cannot
make sure precise booting time, we suggest you set it longer.