HOW TO INSTALL
Install an all-pole switch with the contact separation
not less than 3 mm and a leakage protection switch
(with the leakage current lower than 30 mA)between
the fixed wring and the main body of this product.
請於 固定 佈線與本 產品 主機間安 裝觸 點開距不小於3 mm的
"電 源全 極開關" 及漏 電保護開 關(洩 漏電 流在30 mA以 下)。
Notice
提示事項
Please select the suitable all-pole switch and leakage
protection switch according to locally relevant
Electricity and Wiring Regulations .
請根據當 地 相關的電力 線 路規範選擇合 適的 "電源全 極開
關"和" 漏 電保護開關 " 。
Remove the screws (2 pcs) on the cord cover,
and open the cord cover and the internal
cord cover (by pushing the clamping
position outward).
取下接線 蓋 板上的螺絲( 2顆),
打開接線 蓋 板及內接線 蓋 板。
Loosenthescrewsofthecordclip.
將固定電源 線線 夾的螺絲 鬆脫 。
Loosen the screws of the pillar terminal,
insert the power cord (not supplied)
connected to the indoor fixed wiring into
the pillar terminal according to the marks,
tighten the screw, and guide the wire
according to the right figure.
鬆 開 接線柱 上的螺 絲 ,將接 入 室內固 定 線路的 電
源 線(用 戶自購)按 標 註插入 接 線柱, 擰 緊接 線 柱
螺 絲 ,並按 右圖進 行 理線。
Fix the power cord with the cord clip.
(The cord clip must pin the insulation
sheath of power cord.)
用 電源線 線 夾將電 源 線固定 。
(電 源線 線 夾必須 壓 住電 源 線絕緣 護 套)
Put the internal cord cover and the
cord cover back on, and use the screw
removed in Step
again.
將內接 線 蓋板及 接 線蓋 板 重新蓋 好 ,用步
拆 下 的螺 絲 ,將接 線 蓋板重 新 固定。
10
to fix the cord cover
Cord cover
接線 蓋板
Internal
cord cover
內接 線蓋 板
Diagram with the cover removed
Screws (2 pcs)
固定 螺絲(2顆)
安裝 方 法
漏電保護開關(另購)
固定佈線
本產品主機
電源全極開關(另購)
Screws (2 pcs)
固定 螺絲( 2顆)
打開後示 意 圖
Insulation
sheath
絕緣 護 套
Cord clip
線夾
Screw
螺絲
Cord clip
線 夾