  • Page 1 18Gbps 4 x 4 HDBaseT (150M) Matrix iMatrix H44H150 VER 1.0 www.infobitav.com...
  • Page 2: Table Of Contents

    Thank you for purchasing this product For optimum performance and safety, please read these instructions carefully before connecting, operating or adjusting this product. Please keep this manual for future reference. Surge protection device recommended This product contains sensitive electrical components that may be damaged by electrical spikes, surges, electric shock, lighting strikes, etc.
  • Page 3: Introduction

    1. Introduction The 18Gbps 4x4 HDBaseT(150M) Matrix can connect four HDMI sources to eight displays. It features four HDMI outputs and each HDMI output is mirrored to provide a CAT-Cable output which runs simultaneously. HDBaseT output can extend video transmission distance up to 492ft / 150m via a single Cat 5e/6/7 cable and the resolution is up to 4K2K@60Hz 4:4:4.
  • Page 4: Package Contents

    3. Package Contents ① 1 x 18Gbps 4x4 HDBaseT(150M) Matrix ② 4 x HDBaseT Receiver ③ 1 x Matrix IR Remote ④ 1 x 100~240V AC 50/60Hz Power cable ⑤ 1 x RS-232 serial cable (1.5 meters, male to female head) ⑥...
  • Page 5 Connection Inputs: 4 x HDMI Type A [19-pin female] Outputs: 4 x HDMI Type A [19-pin female] 4 × HDBaseT port [RJ45] 4 × Coaxial audio [3.5mm Stereo Mini-jack] 4 × balanced analog audio [5-pin Phoenix Matrix connector] Controls: 5 x IR IN [3.5mm Stereo Mini-jack] 5 x IR OUT [3.5mm Stereo Mini-jack] 1 ×...
  • Page 6: Operation Controls And Functions

    5. Operation Controls and Functions 5.1 Matrix Panel Front Panel MENU POWER OUTPUT INPUT ENTER DOWN LOCK Name Function Description Display matrix switching status, input / output port, EDID, OLED screen Baud rate, IP Address. The LED will illuminate in green when the product is working Power LED normally, and red when the product is on standby.
  • Page 7 Rear Panel AUDIO OUT IR IN IR OUT COAX 1 COAX 2 COAX 3 COAX 4 OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 TCP/IP RS-232 100-240V AC 50/60HZ HDMI HDBT HDMI HDBT INPUT HDMI HDBT HDMI HDBT CONTROL Name Function Description IR IN (1/2/3/4/ Connect to IR receiver cable, the IR receive signal will emit...
  • Page 8: Hdbaset Receiver Panel

    5.2 HDBaseT Receiver Panel SERVICE HDMI OUT AUDIO OUT IR IN IR OUT Name Function Description Power LED Red LED will be on when the receiver is powered on. SERVICE port Firmware update port. DC 24V/1A power supply input port. Note: The Matrix supports POC function, it means that either DC 24V transmitter or receiver is powered on by 24V/1A power adapter,...
  • Page 9: Ir Remote

    6. IR Remote ① Power on or Standby: Power on the Matrix or set it to standby mode. ② Output 1: Press 1\2\3\4 button to select input source to HDMI OUTPUT 1. ③ Output 2: Press 1\2\3\4 button to select input source to HDMI OUTPUT 2.
  • Page 10: Ir Control System

    7. IR Control System The product is not only a matrix switch but also an extender. It supports bi-directional IR control. When Matrix is connected to HDBaseT Receiver through Cat 5e/6/7 cable, you can control remote display device (HDBaseT) or input source device (Matrix) through IR signal transmission.
  • Page 11 At HDBaseT receiver (Remote end): IR signal follows video switch to change. For example, the HDMI output signal on the HDBaseT Receiver 1 is from the HDMI INPUT 2 port, so IR input signal of the HDBaseT Receiver 1 will emit to IR OUT 2 port of the Matrix. The HDMI output signal on the HDBaseT Receiver 3 is from the HDMI INPUT 4 port.
  • Page 12: Ir Cable Pin Assignment

    8. IR Cable Pin Assignment IR RECEIVER IR BLASTER 9. EDID Management This Matrix has 21 factory defined EDID settings, 2 user-defined EDID modes and 8 copy EDID modes. You can select defined EDID mode or copy EDID mode to input port through on-panel button, RS-232 control or Web GUI.
  • Page 13 The defined EDID setting list of the product is shown as below: EDID Mode EDID Description 1080p, Stereo Audio 2.0 1080p, Dolby/DTS 5.1 1080p, HD Audio 7.1 1080i, Stereo Audio 2.0 1080i, Dolby/DTS 5.1 1080i, HD Audio 7.1 3D, Stereo Audio 2.0 3D, Dolby/DTS 5.1 3D, HD Audio 7.1 4K2K30_444, Stereo Audio 2.0...
  • Page 14: Web Gui User Guide

    10. Web GUI User Guide The Matrix can be controlled by Web GUI. The operation method is shown as below: Step 1: Get the current IP Address. The default IP address is 192.168.1.100. You can get the current Matrix IP address in two ways: The first way: You can get the IP address via panel buttons.
  • Page 15 After entering the Web GUI page, there will be a Login page, as shown below: Select the Username from the list and enter the password. The default passwords are: User Admin Username Password user admin After entering the password, click the “LOGIN” button and the following Status page will appear.
  • Page 16 ■ Video Page You can do the following operations on the Video page: ① Output: The current device’s OUTPUT port. You can select signal source for it. ② Input: You can click the drop-down menu to select signal source for the corresponding OUTPUT port .
  • Page 17 Set EDID for the User Click the “Browse” button, then select the bin file. If you select the wrong EDID file, there will be a prompt, as shown in the following figure: Make sure to select the correct file, then you can check the name of the selected file. Select “User 1”...
  • Page 18 ■ CEC Page You can perform CEC management on this page: ① Input Control: You can control the operation of each input source by pressing the icons on the page. (You can control multiple inputs simultaneously.) ② Output Control: You can control the operation of each display, such as power on/off, volume +/-, active source switching.
  • Page 19 Click “OK” to search the IP Address again, as shown in the following figure: After searching is completed, it will switch to the login page, the default network setting is completed. Modify User Password Click the “User” button, enter the correct Old Password, New Password, and Confirm Password, then click “Save”.
  • Page 20 ■ System Page ① Panel Lock: Click to lock/unlock panel buttons. “On” indicates that panel buttons are unavailable; “Off” indicates panel buttons are available. ② Beep: Click to turn on/off the beep. ③ LCD: You can turn on/off the LCD, and set the turn-on time (15s/30s/60s). ④...
  • Page 21: Rs-232 Control Command

    11. RS-232 Control Command The product also supports RS-232 control. You need a serial cable with RS-232 male head and DB9 transfer USB male head. The RS-232 head of the serial cable is connected to the RS-232 control port with DB 9 at the rear of the Matrix, and the USB head of the serial cable is connected to a PC.
  • Page 22 Example Function Description Feedback Command Code Default Setting Get the connection status of the r link in x! r link in 1! hdmi input 1: connect x input port,x=0~4(0=all) Get the connection status of the hdmi output 1: connect r link out y! r link out 1! y output port,y=0~4(0=all) hdbt output 1: connect...
  • Page 23 Example Function Description Feedback Command Code Default Setting enable hdbt output 1 stream disable hdbt output 1 Set hdbt output y stream on/off, s hdbt 1 stream 1! stream s hdbt y stream z! y=0~4(0=all) enable z=0~1(0:disable,1:enable) s hdbt 0 stream 1! enable hdbt all outputs stream disable hdbt all outputs...
  • Page 24 Example Function Description Feedback Command Code Default Setting r edid data hdmi y! Get the EDID data of the hdmi EDID: 00 FF FF FF FF r edid data hdmi 1! output y port,y=1~4 FF FF 00 ……… Get the EDID data of the hdbt EDID: 00 FF FF FF FF r edid data hdbt y! r edid data hdbt 1!
  • Page 25 Example Function Description Feedback Command Code Default Setting Network Setting IP Mode: Static IP: 192.168.1.72 Subnet Mask: 255.255.255.0 r ipconfig! Get the Current IP Configuration r ipconfig! Gateway: 192.168.1.1 TCP/IP port=8000 Telnet port=10 Mac address: 00:1C:91:03:80:01 Mac address: r mac addr! Get network MAC address r mac addr! 00:1C:91:03:80:01...
  • Page 26 Example Function Description Feedback Command Code Default Setting Network reboot… IP Mode: Static IP: 192.168.1.72 Subnet Mask: 255.255.255.0 s net reboot! Reboot network modules s net reboot! Gateway: 192.168.1.1 TCP/IP port=8000 Telnet port=10 Mac address: 00:1C:91:03:80:01 Set the data length of x hdbt uart, hdbt uart1 data len is s uart x datalen y! s uart 1 datalen 1!
  • Page 27: Application Example

    12. Application Example Amplifier 2.0 Speakers Power Supply AUDIO OUT IR IN IR OUT COAX 1 COAX 2 COAX 3 COAX 4 OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 TCP/IP RS-232 100-240V AC 50/60HZ HDMI HDBT HDMI HDBT INPUT HDMI HDBT HDMI...