Hide thumbs Also See for 85409576:

Advertisement

Quick Links

Table of Content 85409576
..................................................................................................................................
.........................................................................................................................................
..............................................................................................................................
.......................................................................................................................................
..................................................................................................................................
Version Nr. 1-11 - 05.10.2022
.........................................................................................................................
......................................................................................................................
.....................................................................................................................
......................................................................................................................
.....................................................................................................................
..................................................................................................................
...............................................................................................................
.........................................................................................................................
..............................................................................................................
......................................................................................................................
.........................................................................................................
................................................................................................................
..........................................................................
Doc. No. 9985409576
2
2
3
4
5
6
7
8
11
12
13
15
19
20
21
21
22
23
1 / 24

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 85409576 and is the answer not in the manual?

Questions and answers

Summary of Contents for Seifert 85409576

  • Page 1: Table Of Contents

    Table of Content 85409576 1. User manual ..........................2. Legal regulations ......................... 3. Safety instructions ........................4. Settings ............................5. Functional principle ........................6. Technical data ..........................7. Performance graph ........................8. Mounting ............................9. Mounting Principle ........................10. Cut out dimensions ........................
  • Page 2: User Manual

    1. User manual This instruction manual contains information and instructions to enable the user to work safely, correctly and economically on the unit. Understanding and adhering to the manual can help one: Avoid any dangers. Reduce repair costs and stoppages. Extend and improve the reliability and working life of the unit.
  • Page 3: Safety Instructions

    Disregarding the instruction manual Operating error Inappropriate work on or with the unit The use of non-specified spare parts and accessories Unauthorised modifications or changes to the unit by the user or his personnel The supplier is only liable for errors and omissions as outlined in the guarantee conditions contained in the main contractual agreement.
  • Page 4: Settings

    4. Settings The cooling unit is intended to be used as a complementary accessory to larger industrial equipment. The unit is used where heat needs to be dissipated from electrical control cabinets or similar enclosures in order to protect heat sensitive components. It is not intended for household use. The unit has two completely separate air circuits which ensure that the clean cabinet air does not come into contact with the ambient air which may well be dirty or polluted.
  • Page 5: Functional Principle

    5. Functional principle The cooling unit for industrial enclosures works on the basis of a refrigeration circuit consisting of four main components; a compressor, an evaporator, a condenser and an expansion device. The circuit is hermetically sealed and R134a refrigerant circulates inside it (R134a is chlorine free and has an Ozone Destruction Potential [ODP] of 0 and a Global Warming Potential [GWP] of 1430).
  • Page 6: Technical Data

    6. Technical data Order Number 85409576 13650 BTU @ 50 Hz Cooling capacity 95F/95F 14330 BTU @ 60 Hz 11950 BTU @ 50 Hz Cooling capacity 95F/122F 13300 BTU @ 60 Hz Compressor type Rotary piston Refrigerant / GWP R134a / 1430 Refrigerant charge 585 g / 20.6 oz...
  • Page 7: Performance Graph

    7. Performance graph Version Nr. 1-11 - 05.10.2022 Doc. No. 9985409576 7 / 24...
  • Page 8: Mounting

    8. Mounting The power supply rating on unit rating plate must comply with mains rating. Always disconnect the power supply before opening the unit. The heat load to be dissipated from enclosure should not exceed specific cooling output of the unit at any condition.
  • Page 9 Cold air outlet duct: When using a cold air outlet duct please follow the steps below. Filter installation: If you install / replace a filter please follow the steps below. Version Nr. 1-11 - 05.10.2022 Doc. No. 9985409576 9 / 24...
  • Page 10 Applying supplied tight tape Condensate management: High humidity and low temperatures inside the enclosure can lead to condensation on the evaporator. Condensate that flows back into the enclosure can damage sensitive control electronics. The integrated condensate evaporation of the cooling unit releases the condensate to the environment. If condensate formation is too great, additional condensate can drip into an overflow trough, which then drains off...
  • Page 11: Mounting Principle

    9. Mounting Principle NOTES: • Do not use within the first 15 minutes after installation! • Use only the supplied mounting hardware. • Tighten Screws to 4.5 Nm. • Ensure the mounting surface does not warp after assembly and reinforce it if necessary. M6 screws M6 toothed washers M6 flat washers...
  • Page 12: Cut Out Dimensions

    10. Cut out dimensions Version Nr. 1-11 - 05.10.2022 Doc. No. 9985409576 12 / 24...
  • Page 13: Electrical Connection

    Fluorescent lamps with electronic controllers or without phase shifting capacitors can be used, depending on the operating limits specified for each type of relay. SCCR Refer to UL508A Supplement SB and Seifert Systems’ document Short Circuit Current Rating (SCCR) on methods how to modify the available short circuit current within a circuit in the panel.
  • Page 14 Connect unit: Connect the cooling device according to the instructions below. The cable cross-section must correspond to the required power for the current consumption, but max. 2.5 mm² / AWG 14. Version Nr. 1-11 - 05.10.2022 Doc. No. 9985409576 14 / 24...
  • Page 15: Controller

    12. Controller Das Display zeigt Temperaturen im Bereich von -50°C bis +150°C (-58°F to +302°F) an. Die Temperatur wird in Zehnerschritten von -19.9°C bis +99.9°C (-3.8°F bis +211.8°F) angezeigt. Während des Programmierens werden sowohl die Kurzzeichen als auch die jeweiligen Werte angezeigt. Das Display zeigt auch die jeweiligen Symbole entsprechend den Ereignissen an.
  • Page 16 Einstellen der gewünschten Heizungstemperatur St2:(nur für Geräte mit interner Heizung): 1. Die “SET” Taste zweimal langsam drücken bis St2 und dann der voreingestellte Wert ( +5°C / +41°F) erscheinen. 2. Die Tasten ▲ oder ▼ betätigen um den gewünschten Wert auszuwählen. 3.
  • Page 17 Alarm Relais Funktion Es sind sowohl normal geschlossen (NC) als auch normal offen (NO) Alarmkontakte vorhanden. Unter Normalbedingungen ist der NC Kontakt geschlossen und der NO Kontakt offen. Wenn eine Alarmsituation auftritt, öffnet der NC Kontakt und der NO Kontakt schliesst. Zustand Alarmrelais Display...
  • Page 18 Wird während des Programmiervorganges keine Taste innerhalb von 10 Sekunden betätigt, fängt das Display an zublinken und kehrt nach 1 Minute zum Hauptmenü zurück ohne Änderungen zu speichern. Um die Scrollgeschwindigkeit zu ändern drücken und halten Sie die ▲ oder ▼ Tasten für mindestens 5 Sekunden.
  • Page 19: Wiring Diagram

    13. Wiring diagram Anschlußstecker Signalstecker Alarm (NO) Alarm (COM) Alarm (NC) Türkontakt Türkontakt Version Nr. 1-11 - 05.10.2022 Doc. No. 9985409576 19 / 24...
  • Page 20: Taking Into Operation

    14. Taking into operation Attention! The unit can be damaged by lack of lubricant. To ensure that the compressor is adequately lubricated the oil, which has been displaced during transport, must be allowed to flow back into it. The unit must therefore be allowed to stand for at least 30 min.
  • Page 21: Trouble Shooting

    15. Trouble shooting Failure Condition Cause Solution Internal fan does not work Power not connected. Verify power supply Enclosure temperature is below Verify values of parameter setting temperature (St1) "St1" Internal fan works, external fan and compressor don't work Door switch contact is open Verify door switch Controller doesn't work Replace controller...
  • Page 22: Transport & Storage

    17. Transport & Storage Malfunction due to transport damage On delivery the carton box containing the unit must be examined for signs of transport damage. Any transport damage to the carton box could indicate that the unit itself has been damaged in transit which in the worst case could mean that the unit will not function.
  • Page 23: Parts Supplied / Spare Parts / Accessories

    18. Parts supplied / Spare parts / Accessories Seifert Systems GmbH Seifert Systems Ltd. Seifert Systems AG Seifert Systems GmbH Seifert Systems Ltd. Seifert Systems Inc. Seifert Systems Pty Ltd. Albert-Einstein-Str. 3 HF09/10 Wilerstrasse 16 Bärnthal 1 Rep. Office 75 Circuit Drive...
  • Page 24 info.de@seifertsystems.com info@seifertsystems.com info.ch@seifertsystems.com info.at@seifertsystem.com info@seifertsystems.com info.us@seifertsystems.com info@seifertsystems.com.au Version Nr. 1-11 - 05.10.2022 Doc. No. 9985409576 24 / 24...