Advertisement

Quick Links

Table of Content 43042001
..................................................................................................................................
.........................................................................................................................................
..............................................................................................................................
.......................................................................................................................................
..................................................................................................................................
Version No. 1-8 - 04.06.2022
.........................................................................................................................
......................................................................................................................
.....................................................................................................................
......................................................................................................................
.........................................................................................................
..................................................................................................................
...................................................................................................................
............................................................................................................
...............................................................................................................
........................................................................................................................
.............................................................................................................
.....................................................................................................................
.........................................................................................................
................................................................................................................
..........................................................................
Doc. No. 9943042001
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
17
17
18
19
1 / 19

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 43042001 and is the answer not in the manual?

Questions and answers

Summary of Contents for Seifert 43042001

  • Page 1: Table Of Contents

    Table of Content 43042001 1. User manual ..........................2. Legal regulations ......................... 3. Safety instructions ........................4. Settings ............................5. Functional principle ........................6. Technical data ..........................7. Performance graph ........................8. Mounting ............................9. Condensate management ......................10. Mounting Principle ........................
  • Page 2: User Manual

    1. User manual This instruction manual contains information and instructions to enable the user to work safely, correctly and economically on the unit. Understanding and adhering to the manual can help one: Avoid any dangers. Reduce repair costs and stoppages. Extend and improve the reliability and working life of the unit.
  • Page 3: Legal Regulations

    2. Legal regulations Liability The information, data and instructions contained in this instruction manual are current at the time of going to press. We reserve the right to make technical changes to the unit in the course of its development. Therefore, no claims can be accepted for previously delivered units based on the information, diagrams or descriptions contained in this manual.
  • Page 4: Safety Instructions

    3. Safety instructions Upon delivery the unit is already meeting current technical standards and can therefore be safely taken into operation. Only authorised personnel is allowed to work on the unit. Unauthorised personnel must be prohibited from working on the unit. Operating personnel must inform their superiors immediately of any malfunction of the unit.
  • Page 5: Settings

    4. Settings The cooling unit is intended to be used as a complementary accessory to larger industrial equipment. The unit is used where heat needs to be dissipated from electrical control cabinets or similar enclosures in order to protect heat sensitive components. It is not intended for household use. The unit has two completely separate air circuits which ensure that the clean cabinet air does not come into contact with the ambient air which may well be dirty or polluted.
  • Page 6: Functional Principle

    5. Functional principle The cooling unit for enclosures works on the basis of a refrigeration circuit consisting of four main components: compressor (1), evaporator (2), condenser (3) and expansion device (4). The circuit is hermetically sealed and R134a refrigerant circulates inside it (R134a is chlorine free and has an Ozone Destruction Potential [ODP] of 0 and a Global Warming Potential [GWP] of 1430).
  • Page 7: Technical Data

    6. Technical data Order Number 43042001 320 W @ 50 Hz Cooling capacity L35L35 360 W @ 60 Hz 200 W @ 50 Hz Cooling capacity L35L50 220 W @ 60 Hz Compressor type Reciprocating compressor Refrigerant / GWP R134a / 1430 Refrigerant charge 79 g / 2.78 oz...
  • Page 8: Performance Graph

    7. Performance graph Version No. 1-8 - 04.06.2022 Doc. No. 9943042001 8 / 19...
  • Page 9: Mounting

    8. Mounting The power supply rating on unit rating plate must comply with mains rating. Always disconnect the power supply before opening the unit. The heat load to be dissipated from enclosure should not exceed specific cooling output of the unit at any condition.
  • Page 10: Condensate Management

    9. Condensate management The condensation drain is in the base of the unit. The condensation drain pipe should be attached as required e.g. in conditions of high humidity. To install a drain pipe, please follow below steps: Remove the plastic stopper from in the base of the unit (factory setting is locked) Dispose the plastic stopper but keep the Silicon washer Insert the drain connector Lock it clockwise and fix the oil &...
  • Page 11: Mounting Principle

    10. Mounting Principle Do not use within the first 15 minutes after installation! M6 screws M6 flat washers M6 toothed washers Cabinet Sealing tape Cooling unit Version No. 1-8 - 04.06.2022 Doc. No. 9943042001 11 / 19...
  • Page 12: Cut Out Dimension

    11. Cut Out Dimension Version No. 1-8 - 04.06.2022 Doc. No. 9943042001 12 / 19...
  • Page 13: Dimension (H X W X D)

    12. Dimension (H x W x D) Version No. 1-8 - 04.06.2022 Doc. No. 9943042001 13 / 19...
  • Page 14: Electrical Connection

    Fluorescent lamps with electronic controllers or without phase shifting capacitors can be used, depending on the operating limits specified for each type of relay. SCCR Refer to UL508A Supplement SB and Seifert Systems’ document Short Circuit Current Rating (SCCR) on methods how to modify the available short circuit current within a circuit in the panel.
  • Page 15: Controller

    14. Controller The unit is equipped with a temperature controller which regulates the function of the air-conditioning cycle. At normal working conditions the display shows the temperature inside the enclosure. The cooling set point for the interior of the enclosure (parameter St / St1) is pre-set at 35°C and can be adjusted between 20°C and 50°C.
  • Page 16: Wiring Diagram

    15. Wiring Diagram Version No. 1-8 - 04.06.2022 Doc. No. 9943042001 16 / 19...
  • Page 17: Taking Into Operation

    16. Taking into Operation Attention! The unit can be damaged by lack of lubricant. To ensure that the compressor is adequately lubricated the oil, which has been displaced during transport, must be allowed to flow back into it. The unit must therefore be allowed to stand for at least 30 min.
  • Page 18: Transport & Storage

    19. Transport & Storage Malfunction due to transport damage On delivery the carton box containing the unit must be examined for signs of transport damage. Any transport damage to the carton box could indicate that the unit itself has been damaged in transit which in the worst case could mean that the unit will not function.
  • Page 19: Parts Supplied / Spare Parts / Accessories

    Door contact switch 3100001 Seifert Systems GmbH Seifert Systems Ltd. Seifert Systems AG Seifert Systems GmbH Seifert Systems Ltd. Seifert Systems Inc. Seifert Systems Pty Ltd. Albert-Einstein-Str. 3 HF09/10 Wilerstrasse 16 Bärnthal 1 Rep. Office 75 Circuit Drive 105 Lewis Road...

Table of Contents