General Information; Technical Data - Helios AIR1-KP Installation And Operating Instructions Manual

Condensate pump
Table of Contents

Advertisement

Available languages

Available languages

Installation and Operating Instructions
EN
CHAPTER 1
GENERAL
INFORMATION
m
m
ATTENTION
CHAPTER 2

TECHNICAL DATA

Condensate pump AIR1-KP
1.0 Important information
In order to ensure correct operation and for your own safety, please read and observe
the following instructions carefully before proceeding. Relevant national standards, safety
regulations and provisions (e.g. DIN EN VDE 0100) as well as the technical connection
conditions of the energy supply company must be observed and applied.
Keep the operating instructions close to the unit for easy reference. After the final assem-
bly, the document must be issued to the operator (tenant/owner).
1.1 Warning and safety instructions
The adjacent symbol is a safety-relevant prominent warning label. All safety re-
gulations and/or symbols must be absolutely adhered to, so that any dangerous
situation is avoided.
1.2 Warranty claims – Exclusion of liability
Our warranty shall not apply if the following instructions are not observed. The same
applies for liability claims against the manufacturer. The use of accessories, which are
not recommended or offered by Helios, is not permitted. Any damage that may occur is
not liable for warranty.
1.3 Regulations – Guidelines
If the product is installed correctly and used to its intended purpose, it conforms to all
applicable regulations and EC guidelines at its date of manufacture.
1.4 Receipt
Please check delivery immediately on receipt for accuracy and damage. If damaged,
please notify the carrier immediately. In case of delayed notification, any possible claim
may be void.
1.5 Storage
When storing for a prolonged time the following steps are to be taken to avoid damaging
influences:
Protection by dry, air- dustproof packing (plastic bags with drying agent and moisture
indicators). The storage place must be waterproof, vibration-free and free of excessive
temperature variations (-20 to +60 °C). Damages due to improper transportation, storage
or commissioning are verifiable and not liable for warranty.
1.6 Intended use
Condensate can be easily removed from the condensate pipe or raised to a certain height with
the condensate pump.
The condensate pump AIR1-KP can be connected to AIR1 ventilation units in series XC
and to the corresponding cooling registers (Helios range).
Any use other than the intended use is prohibited!
2.0 Technical data
AIR1-KP XC 500-1400
Flow rate max.
Suction head max.
Discharge head max.
Power supply
Voltage
Operating temperature
Water temperature max.
Protection category
13 l/h
1.5 m
10 m
19 W
220-240 V 50/60 Hz
5-45 °C
35 °C
IP20
1