Download Print this page

Maintenance; Manufacturer's Declaration - EM-Technik 4L Assembly And Operation Instructions Manual

Advertisement

5.3 Reading the Measured Value
• The position of the fl oat in the metering tube corre-
sponds to the volumetric fl ow of the medium.
• Parallax-free reading: Look over the top edge of the
fl oat and read the measured value on the scale.

6 Maintenance

• When used as designated, the fi tting is practically
wear-free and generally requires no maintenance.
• The operating company must perform regular visual
inspections of the fi tting according to the operating
conditions to prevent leaks and damage.
7 Disposal
• When disposing of the fi tting and packaging, comply
with the relevant disposal requirements and environ-
mental protection regulations.
• When disposing of fi ttings, pay careful attention to any
residues of toxic or corrosive media.
8 Return Delivery
Do not return before consulting with emtechnik.
1. Please consult with emtechnik.
2. Empty the fi tting properly.
3. Rinse and clean the fi tting thoroughly, especially if the
media is being conveyed are harmful, explosive, hot,
or hazardous in some other way.
4. For fi ttings that have been operated with aggressive,
corrosive, combustible, toxic or water polluting media,
a completely fi lled in clearance certifi cate must always
be included.
EM-Technik GmbH - Industriestraße 2 - 67133 Maxdorf - Germany
info@em-technik.com
9 Troubleshooting /
Fault Rectifi cation
Error
Possible Cause
The fi tting does not
Foreign object in the
open/close or not
fi tting
completely
Connection between
Sealing surface
fi tting and pipeline is
damaged
leaking
Fitting is leaking
Fitting faulty

10 Manufacturer's Declaration

• Our products do not fall under the scope of the Ma-
chinery Directive 2006/42/EC. However, they can be
incorporated in an installation that is considered as
machinery. In this case regard the following note: The
products may not be put into operation until it is made
sure that the fi nal machinery into which our products
are incorporated complies with the provisions of the
Machinery Directive 2006/42/EC.
• Based on the fl uid class, pressure and nominal diame-
ter, our products fall under diagram 8 of the Pressure
Equipment Directive PED 2014/68/EU. Because of the
ratio of nominal diameter, pressure and volume, they
fall only under article 4 paragraph 3 and are designed
and manufactured according to applicable good engi-
neering practice. They must not carry any CE marking.
• The warranty of armature expires in the following ca-
ses: Operating conditions which do not follow the in-
tended use or do not follow technical specifi cations.
Improper installation or assembly. Just as well as inap-
propriate use, dismantling or modifi cation.
• Failure to observe information provided here may lead
to injuries, material damage, malfunctions and impuri-
ties due to escaping medium.
11 Contact
In case of questions or suggestions please contact us:
EM-Technik GmbH
Industriestr. 2
Tel
67133 Maxdorf
Fax +49 6237 407-77
Germany
info@em-technik.com
www.em-technik.com
Error Rectifi cation
Flush the fi tting
Use sealant,
see 4.3
Check fi tting for
damage and replace
it if necessary
+49 6237 407-0
6

Advertisement

loading