Installation / Operating
IP65 LED Floodlight Fittings
Part numbers:
LEDFL10, LEDFL20, LEDFL30, LEDFL50,
LEDFL80, LEDFL120 & LEDFL150
IMPORTANT INFORMATION
This product should be installed by a
competent person and in accordance with
the IET Wiring Regulations.
If in doubt, consult a qualified electrician.
These instructions should be read carefully
prior to any installation and retained after
completion for further reference and
instructions to the building owner/occupier
after installation.
Always turn off the power source before
commencing work on this device.
INSTALLATION INSTRUCTIONS
This luminaire is water resistant to IP65 but
it is advisable, wherever possible, to locate it
in a sheltered location. No modification
should be made to the casing to preserve the
moisture properties and warranty.
This fitting is supplied pre-wired with 0.9M
of three core cable (Live, Neutral and Earth).
This cable can NOT be removed. Connection
must be made via a suitable terminal box.
Should the flex become damaged it should
be replaced with cable of the same
specification and only by a competent
person. To avoid a heat build up it is
advisable that a clear air gap is left around
the luminaire and the front face should be at
least 500mm away from any combustible
surface. The supplied bracket should be used
at all times for mounting.
TECHNICAL INFORMATION
This appliance is designed to work with a
mains voltage of 100V to 250V AC 50Hz.
It should be wired to an appropriately fused
and protected source.
Lumen Output:
Instructions for
IMPORTANT
10W
20W
30W
50W
80W
120W
150W
700lm
1400lm
2100lm
3500lm
5600lm
9000lm
10500lm