Download Print this page

KingShield TXPIR400 Installation Instructions

Xenon floodlight with pir

Advertisement

Quick Links

Installation Instructions

for Xenon Floodlight
TXPIR400 / TXPIR400W
with PIR
IMPORTANT
This product should be installed by a competent
person and in accordance with the current IEE
Wiring Regulations. If in doubt, consult a qualified
electrician.
This floodlight is provided with an infrared
detector. The detector senses 'Warmth
movement' in the surrounding area and
when it is dark. When movement is detected
the lamp will come on. This fitting has no
manual override.
INSTRUCTIONS
Switch the power off before installation
to prevent electric shock.
NOTE 1.
On installation try not to install light
fitting close to a vent such as a vent
from a boiler or tumble dryer as hot
air movement can cause the lamp to
switch on when it is not required to.
NOTE 2.
Passing cars (warm engines) and
nearby trees and bushes can cause
your lamp to switch on, due to a
sudden change in temperature and
gusts of wind. Please bear this in
mind when deciding on where to
install your light.
NOTE 3.
Do not mount the fitting in the ceiling.
NOTE 4.
Please ensure the distance between
the front glass of the lamp and the
surface area the lamp is lighting is at
least 1 metre apart.
1. The lamp fitting can be installed using
the three holes on the mounting
bracket. The bracket should be
horizontally fixed, see Fig. 2.
2. Loosen the supporter bolts to adjust
the installation angle of the lamp in
accordance with the lighting direction
needed. The lighting direction cannot
be adjusted downwards more than
O
45
, see Fig. 2.
ELECTRICAL WIRING
Open the terminal box cover and
unscrew the inlet gland and remove
the sealing ring. Thread the power
cable through the inlet gland and the
sealing ring.
Live = Brown/Red
Neutral = Blue/Black
Earth = Green and Yellow
Insert the wire ends into the terminal
block and then tighten them. Replace
the box cover, screw in the inlet
gland together with the sealing ring.
INSTALLING THE LAMP TUBE
1. Unscrew the bolt and open the glass
holder. Fit the tube into the tube
socket. Keep the waterproof rubber
pad in its original position and close
the glass holder with the bolt.
2. When replacing the lamp - isolate
the fitting from the supply before
opening the glass front. If the lamp
was recently turned off do not touch
the lamp tube with bare hands.
Please follow lamp manufacturers
instructions when fitting the lamp.
3. If glass cover becomes cracked,
replace immediately before using the
lamp again.
OPERATION
The infrared detector is equipped with
three adjusting controls, see fig 3
below.
Time Control
The time adjustment control (on the
left) adjusts the lighting period of the
lamp after the detection of movement.
This period is adjustable from 9 secs to
Fig. 1
Fig. 2
Fig. 3

Advertisement

loading
Need help?

Need help?

Do you have a question about the TXPIR400 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for KingShield TXPIR400

  • Page 1: Installation Instructions

    Thread the power Installation Instructions cable through the inlet gland and the for Xenon Floodlight sealing ring. TXPIR400 / TXPIR400W with PIR Fig. 1 IMPORTANT This product should be installed by a competent person and in accordance with the current IEE Wiring Regulations.
  • Page 2 Fig. 5 The best detection is obtained by approaching the GUARANTEE field of detection Your KingShield Xenon Floodlight with PIR is perpendicular guaranteed for 12 months from to its axis. See Fig. 6 the date of purchase. If the field of This does not affect your statutory rights.

This manual is also suitable for:

Txpir400w