DefendRx® 5000
Electronic Air Purifier
Installation Instructions
•
Turn OFF the POWER to the Furnace/Air Handler and Fan switch.
•
Open the door of the unit and remove the old pleated media (Fig.6).
•
Position the new 5" replacement box such that the metal mesh on
media faces the metal screen of the cabinet, the end with a hole goes
in first, then push the box in strictly following the direction on labels
on the box, (Fig.7).
•
Close the door (Fig. 4 and Fig. 5).
•
Switch the Power back ON.
Fig. 6
WARNINGS
•
The air filter is not energized in the absence of air flow in the HVAC system.
•
CAUTION - THE AIR CLEANER SHALL NOT BE INSTALLED IN A
SYSTEM WITH AIR FLOW LESS THAN 375 CFM, TO ENSURE OZONE
LEVELS ARE NOT EXCEEDED.
•
THIS AIR CLEANER SHALL NOT BE INSTALLED ON THE HOT-AIR
SIDE OF DUCT-TYPE SYSTEMS.
•
The POWER to the Furnace/Air Handler MUST BE TURNED OFF whenever
installing, removing, or replacing the MicroPower Guard air cleaner.
•
Failure to change the Replacement Media on a 6-month Basis could reduce
airflow and cause damage to the heating and cooling system.
•
Only qualified Electricians/HVAC Technicians should perform electrical wiring.
When non-original DefendRx filter media is used, no matter what the makers
claim, we are forced to decline your Lifetime Warranty.
For Technical Assistance call: 1-800-565-5326
Fig. 7
Low Pressure Filter Media DefendRx 5000 5"
OPERATION, INSTALLATION & MAINTENANCE
INSTRUCTION GUIDE
IMPORTANT: Please complete the information below and leave this
brochure with your customer after installation is complete.
INSTALLED BY:
Contractor Name & Phone No.:
PRODUCT INFORMATION:
MODEL: Viking DefendRx 5000 Electronic Air Purifier
FILTER SIZE:
INSTALLATION DATE:
5" Polarized-Media
Electronic Air Cleaner
This product complies with the maximum allowable concentration of ozone of 0.050 parts
per million by volume (ppmv) in a 24 h period. The Health Canada Guideline 2010
recommends that the maximum exposure limit, based on an averaging time of 8 hours, be
0.020 ppmv or less when tested in an ASHRAE 52.2 conforming test duct.