6.4 Sub-package Mode (Mode 2)

Status
M0=0 M1=1 M2=0
Transmitting
Wireless data transmission is available.
Receiving
Wireless data receiving is available.
Baud rate &
Under this mode, the baud rate and air data rate are independent, both receiver and transmitter can have
air data rate
different baud rate but same air data rate.
Very low air data rate can be configured for longer distance, the data continuousness between output data
Advantage
depends on the data packet length.
Since the air data rate is low and the receiver needs to wait for the data packet length or timeout byte numbers, it
Disadvantage
may cause some delay, which depends on the actual value as set.
Applications
Applicable for those applications requiring distance and continuous data while not requiring transmission speed.
1. Air data rate and baud rate are not relative; the values are valid.
2. 0000 and FFFF are the broadcast addresses, which can be used to monitor and broadcast.
3. The addresses and air data rates must be same, but baud rates can be different on both receiver and
Note
transmitter.
4. The size of individual data packet depends on the subpackage size CHAN [7:5] (excluding address and
channel for directional transmission)

6.5 Configuration Mode (Mode 3)

Status
M0=1 M1=1 M2=0
Transmitting
Transmission not available, serial data received will be discarded.
Receiving
Receiving is not available.
Parameter configuration can be made in configuration mode with specific instruction format and UART 9600,
Configuring
8N1.
Chengdu Ebyte Electronic Technology Co,;Ltd
Copyright ©2012–2021,
1. The "wireless air data rate" in the configuration commands is invalid (SPED.210 bits) and software will
calculate automatically.
2. 0000 and FFFF are the broadcast addresses, which can be used to monitor and broadcast.
3. The addresses and baud rates must be same on both receiver and transmitter.
4. In continuous mode, both transmitter and receiver must be same model. For example, E70 (868T14S)
and E70 (868T30S) cannot communicate in continuous mode.
E70-900T30Suser manual
15