FLECK® 125 IN-AND-OUT VALVE
Installation Instructions
COMPONENTS
B
A) Pentair® Fleck 125 In-And-Out Valve
B) Bypass
C) Connector
PRODUCT SPECIFICATIONS AND OPERATION
A
Specification Description
Minimum Pressure
Maximum Pressure
BR42887
Minimum Water Temperature
Maximum Water Temperature
Minimum Ambient Temperature
Maximum Ambient Temperature
Flow Rate
Downflow
Continuous
54.9 GPM
(15 psid drop)
[12.5 m
Peak
70.9 GPM
(25 psid drop)
[16.1 m
Cv
(Flow at 1 psi drop)
4
B
A
A
20 PSI
BR42887
125 PSI
4
34°F (1°C)
110°F (43°C)
34°F (1°C)
125°F (52°C)
62134-01
Upflow
47.4 GPM
/hr]
[10.8 m
/hr]
3
3
61.2 GPM
/hr]
[13.9 m
/hr]
3
3
14.2
12.2
3
4
B
COMPONENTS / ASSEMBLIES TO BE COMPLIANT AND COMPATIBLE WITH EUROPEAN UNION DIRECTIVE 2011/65/EEC (RoHS2) & REGULATION (EC)1907/2006 (REACH) REQUIREMEN
THIS DOCUMENT IS SOLELY THE PROPERTY OF PENTAIR
RESIDENTIAL FILTRATION, LLC. REPRODUCTION, USE
DISCLOSURE, OR TRANSMISSION OF THIS DOCUMENT OR
DETAILS CONTAINED HEREIN, IN PART OR IN WHOLE, IS
PROHIBITED WITHOUT THE WRITTEN CONSENT OF PENTAIR
RESIDENTIAL FILTRATION, LLC ENGINEERING. THIS
DOCUMENT AND ANY COPIES SHALL BE RETURNED TO
PENTAIR RESIDENTIAL FILTRATION, LLC UPON REQUEST.
DO NOT SCALE DRAWING. DIMS. ARE IN INCHES [mm]
B
INTERPRET DIMS AND TOLERANCES PER ASME Y14.5M -2009
4
UNLESS OTHERWISE SPECIFIED:
ALL FINISHED MACHINED SURFACES 125
TOLERANCES:
ANGLES :
1
1 PLACE .X:
.015 [0.38]
2 PLACE .XX:
.01 [0.3]
3 PLACE .XXX:
.005 [0.13]
3
62134-02
Downflow
Upflow
62.3 GPM
62.6 GPM
[14.2 m
/hr]
[14.2 m
/hr]
3
3
80.4 GPM
80.7 GPM
[18.3 m
/hr]
[18.3 m
/hr]
3
3
A
16.1
16.2
BR42887
4
2
3
PCO
ZONE
REV.
B
C
4
A
COMPONENTS / ASSEMBLIES TO BE COMPLIANT AND COMPATIBLE WITH EUROPEAN UNION DIRECTI
THIS DOCUMENT IS SOLELY THE PROPERTY OF PENTAIR
RESIDENTIAL FILTRATION, LLC. REPRODUCTION, USE
DISCLOSURE, OR TRANSMISSION OF THIS DOCUMENT OR
DETAILS CONTAINED HEREIN, IN PART OR IN WHOLE, IS
PROHIBITED WITHOUT THE WRITTEN CONSENT OF PENTAIR
RESIDENTIAL FILTRATION, LLC ENGINEERING. THIS
DOCUMENT AND ANY COPIES SHALL BE RETURNED TO
THIRD ANGLE
PENTAIR RESIDENTIAL FILTRATION, LLC UPON REQUEST.
PROJECTION
DO NOT SCALE DRAWING. DIMS. ARE IN INCHES [mm]
INTERPRET DIMS AND TOLERANCES PER ASME Y14.5M -2009
UNLESS OTHERWISE SPECIFIED:
APPROVALS
DATE
ALL FINISHED MACHINED SURFACES 125
TOLERANCES:
BR42887
4
TITLE
ANGLES :
1
DRAWN
1 PLACE .X:
.015 [0.38]
2 PLACE .XX:
.01 [0.3]
3 PLACE .XXX:
.005 [0.13]
3
APPROVED
OR BETTER.
SIZE
CHECKED
SCALE
2
3
1
2
REVISIONS
DESCRIPTION
ZONE
PCO
REV.
3
THIRD ANGLE
PROJECTION
DATE
APPROVALS
Pentair R
DRAWN
Filtratio
TOP VIEW
APPROVED
OR BETTER.
3
CHECKED
2
B
DWG NO.
S
1:2
1