Advertisement

Quick Links

PAH300・350S24-SERIES
PAH300・350S24 SERIES
■Before using this product
Be sure to take note of precautions and warnings indicated in this manual when using this product. Improper usage may
lead to electric shock or fire. Be sure to read this instruction manual thoroughly before using this product.
■Precautions
● Avoid touching the baseplate and the case of this product because they get hot.
● There are high voltage and high temperature components within this product. Refrain from disassembling this product
or touching its internal components as this may lead to electric shock or burn.
● To avoid unexpected accident from placing hands or face near the unit during operation.
● Verify that connection to input, output and signal terminals are correct as indicated in this instruction manual.
● For acquisition of various Safety Standards and safety improvement, be sure to use an external fuse.
● This product is designed for installation on electronic equipment.
● For input terminals of 24 V input models, apply a voltage from a primary source with reinforced or double insulation.
● Output voltage of this product is considered to have hazardous energy level (voltage of 2V and above with power of
240W and above) and must not have physical contact with operator. Protection must be provided on this module when
installed on equipment to prevent physical contact with service technician himself or accidentally dropped tools during
repair. Before repair, be sure to turn off the input source and confirm that input and output voltage have drop down to a
safe level.
● Application circuit or component values described in this instruction manual are for reference only. When designing
circuit, be sure to verify actual circuit operation before determining final application circuit or component values.
● Contents of this instruction manual are subject to change without notice. When using this product, please refer to latest
data sheet to satisfy this product specification.
● No part of this document may be copied or reproduced in any for, or by any mean without prior written consent of
TDK-Lambda.
Instruction Manual
TDK-Lambda
C175-04-11B

Advertisement

Table of Contents
loading

Summary of Contents for TDK-Lambda PAH300 Series

  • Page 1 ● Contents of this instruction manual are subject to change without notice. When using this product, please refer to latest data sheet to satisfy this product specification. ● No part of this document may be copied or reproduced in any for, or by any mean without prior written consent of TDK-Lambda. TDK-Lambda C175-04-11B...
  • Page 2: Table Of Contents

    Storage Ambient Humidity Cooling Method Baseplate temperature vs. output voltage drift Withstand Voltage Insulation Resistance Vibration Shock CE MARKING / UKCA MARKING ■ Installation Mounting Method Heatsink Installation Regarding Vibration Recommended Soldering Condition Recommended Cleaning Condition ■ Before concluding module damage TDK-Lambda...
  • Page 3: Block Diagram

    (For Standard Model with Negative logic for ON/OFF control.) Input V oltage O VP Set P oint O C P S et Point V out Output V oltage Reset M ore than 100m s ON/OFF Control *1 level : 4≦H≦35(V) or Open 0≦L≦0.8(V) or Short TDK-Lambda...
  • Page 4: Terminal Explanation

    TRM : Output Voltage Trimming Terminal +Vin : +Input Terminal : +Remote Sensing Terminal : +Output Terminal Baseplate can be connected to FG (frame ground) M3 threaded holes. (standard model) Connect +Vin, -Vin, +V, -V with consideration of contacting resistance. TDK-Lambda...
  • Page 5: Explanation On Specifications

    Also, take note that output spike noise voltage could vary according to PCB (printed circuit board) wiring M3 threaded hole design. Fig.1-2 Basic Connection However, for cases where baseplate is connected to +V or –V, use the nearest M3 threaded hole. (M3 threaded TDK-Lambda...
  • Page 6 -Vin power module from the active line. For this case, connect an additional electrolytic capacitor C6 as shown in fig.1-3 and fig. 1-4. Fig.1-5 Protection for Reversed Connection of Input TDK-Lambda...
  • Page 7 When selecting input filter, be sure to verify actual EMI characteristics (CE and RE) before finalizing the filter. Refer to PAH300・350S24-* Evaluation Data for details. TDK-Lambda...
  • Page 8 Below graph is relation Δ(%) and value of Below graph is relation Δ(%) and value of external resistor. external resistor. 1000 10000 1000 Change in Output Voltage Δ(%) Change in Output Voltage Δ(%) Fig.2-3 Δ(%) vs. Radj(down) (1) Fig.2-5 Δ% vs.Radj(up) (2) TDK-Lambda...
  • Page 9: Maximum Output Ripple And Noise

    –V and – This power module has built-in OCP function. S terminals is within 2V or less. Even for remote Output will recover when short circuit or overload sensing case, use power module such that output power TDK-Lambda...
  • Page 10: On/Off Control (Cnt Terminal)

    Fig.12-1 Series Operation due to High Output 3. When using long wiring, for prevention of noise, Voltage attach a 0.1µF capacitor between CNT terminal and –Vin terminal. 4. At L level, maximum source current from CNT terminal to –Vin terminal is 0.5mA TDK-Lambda...
  • Page 11: Operating Ambient Temperature

    For better improvement of power module reliability, Connect the terminals as shown in the diagram below. derating of baseplate temperature when using is recommended. 14. Operating Ambient Humidity Take note that moisture could lead to power module abnormal operation or damage. TDK-Lambda...
  • Page 12: Insulation Resistance

    UKCA Marking, when applied to a product or packing material for a product covered by this handbook, indicates compliance with the Electrical Equipment (Safety) Regulations and Restriction of the Use of Certain Hazardous Substances in Electrical & Electronic Equipment Regulations. TDK-Lambda...
  • Page 13: Installation

    (1) Method to Fix to confirm on manufacturers of printed circuit board for (1-1) Standard model and /P option model designing pattern. To fix a power module onto printed circuit board, use M3 screws and mount it to the M3 threaded holes TDK-Lambda...
  • Page 14: Heatsink Installation

    (2) Soldering iron φ1.0 mm : 350ºC (60W) within 3 seconds φ2.0 mm : 350ºC (150W) within 20 seconds ※Soldering time changes according to heat capacity of soldering iron, pattern on printed circuit board, etc. Please confirm actual performance. TDK-Lambda...
  • Page 15 ・Is the input or output wire too thin? 5) Output ripple voltage is large ・ Is the measuring method used the same or equivalent with the specified method in the Application Notes? ・Is the input ripple voltage value within the specified value? TDK-Lambda...