Installation Setup Worksheets; 5.3.6.1. Dual Fuel - Indoor Unit Honeywell 2-Stage Ifc Control And Heat; Pump - Lennox HARMONY III Installation, Setup And User Manual

Zoning system
Hide thumbs Also See for HARMONY III:
Table of Contents

Advertisement

5.3.6.

Installation Setup Worksheets

5.3.6.1. Dual Fuel - Indoor Unit Honeywell 2-Stage IFC Control and Heat

Pump

Job Name:
Indoor Unit Model:
Outdoor Unit Model:
Miscellaneous Items:
9 Install Pressure Switch in the outdoor unit per this instructions (27W13 for R410A or 21J18 for
R22)
9 Install Balance Point Sensor (10Z23) as per this installation instruction. Set to desired outdoor
lock out temperature for HP
9 Install Optional Defrost Tempering Sensor 67M41 (if used) per installation instructions. NOTE:
MUST be located in coil delta plate between furnace and coil
9 Install Discharge Air Sensor per installation instructions. The location of the sensor is CRITICAL
for proper system operation
Indoor Unit Setup:
9 Cut on-board link W914 DEHUM OR HARMONY (R to DS) on furnace IFC control (if not cut,
fuse will blow in zone control board)
9 Cut and tape wires from pin # 2 and pin #13 on plug J46 of the VSM wiring harness routed from
the motor to the Furnace Integrated control.
9 Furnace IFC Control DIP switch settings (ON or OFF):
DIP Switch
ON or OFF
1
OFF
2
OFF
3
ON
4
ON
5
6
7
8
9
OFF
10
OFF
11
OFF
12
ON
Condition
DIP switch 1 must be set to OFF for two stage heating
operation
DIP switch 2 determines second stage heat time delay
and is ignored by Harmony III zoning system
DIP switches 3 and 4 determines heating blower off
delay, recommended is 180 sec
DIP switches 5 and 6 determines second stage cooling
blower speed or maximum system air vol.
DIP switches 7 and 8 determine blower "adjust" setting
for maximum system air volume
DIP switches 9 and 10 determines cooling blower
ramping profile and is ignored by Harmony III zoning
system
DIP switches 11 and 12 determines heating blower
speed and is ignored by Harmony III zoning system
Panel Setup:
√ Heating staging jumper
Circle one: 85 90 100
110 120 130
√ Zone 1 PIAB 140F DAS
Circle one: Yes No
jumper in place
√ Cooling staging jumper
Circle one: 50 55 60
√ Cont. Air Reduction jumper
Circle one: 0 25 50
75
√ Heating Air Reduction jumper
Circle one: 0 20 40
√ System Configuration
Circle one: HP GAS
jumpers
√ Stages
Circle one: 2COOL
1COOL
√ Stages
Circle one: 2HP 1HP
√ E-HEAT Stages
Circle one: DF 1 2 3
√ Desired total system CFM
Total system CFM per
with all zones calling:
tables:
√ Zone 1
Name:
Desired CFM:
√ Zone 2
Name:
Desired CFM:
√ Zone 3
Name:
Desired CFM:
√ Zone 4
Name:
Desired CFM:
NOTE:
All of the above are recommended starting positions for furnace DIP switches and Harmony
III jumpers. Slight variations may be required during system start up and operation checks.
Field Wiring Checklist
Indoor Unit Wiring Completed:
DS on Harmony III to DS on indoor unit connected
C on indoor unit connected to Harmony III transformer C
No connection to Y1 or Y2 on indoor unit.
Outdoor Unit Wiring Completed
Thermostat and Damper Wiring Completed
Discharge Sensor wired to Harmony III zoning system
Heat Pump Pressure Switch wired to Harmony III zoning system
56
Recommended 120 deg-F
See "1.10.4. Zone 1 PIAB Jumpers –
140ºF DAS" on page 10.
Select desired discharge air temp
during cooling
Percentage airflow reduction for
continuous fan operation
Percentage air flow reduction for
heating mode
Set to GAS
Set to match condenser, 1 or 2 stage
Ignored for gas heat, non-heat pump
application
Ignored for gas heat, non-heat pump
application
Minimum CFM:
PIAB Setting:
Actual CFM:
PIAB Setting:
Actual CFM:
PIAB Setting:
Actual CFM:
PIAB Setting:
Actual CFM: