  • Page 1 HS Series Installation & Operating Instructions IN007 Rev N 0419 3 Saber Way, Ward Hill, MA 01835 | radonaway.com...
  • Page 2 2. WARNING! Check voltage at the fan to ensure it corresponds with nameplate. See Vapor Intrusion Application Note #AN001 for important information on VI Applications. RadonAway.com/vapor-intrusion 3. WARNING! Normal operation of this device may affect the combustion airflow needed for safe operation of fuel burning equipment.
  • Page 3: System Design Considerations

    In the event that a temporary high water table results in water at or above slab level, water will be drawn into the riser pipes thus blocking air flow to the HS Series Fan. The lack of cooling air will result in the HS Series Fan cycling on and off as the internal temperature rises above the thermal cutoff and falls upon shutoff.
  • Page 4: Electrical Wiring

    1.7 SLAB COVERAGE The HS Series Fan can provide coverage of well over 1000 sq. ft. per slab penetration. This will, of course, depend on the sub-slab aggregate in any particular installation and the diagnostic results. In general, sand and gravel are much looser aggregates than dirt and clay.
  • Page 5: Installation

    2.0 INSTALLATION 2.1 MOUNTING Mount the HS Series Fan to the wall studs, or similar structure, in the selected location with (4) 1/4” x 1 1/2” lag screws (not provided). Ensure the HS Series Fan is both plumb and level.
  • Page 6 Branch lines (if 3 or more) may be 2.0” PVC Pipe Outlet ducting: 2.0” PVC Storage Temperature Range: 32°F-100°F Thermal Cutout: 194°F +/- 9°F (90°C +/- 5°C) Locked rotor protection Internal condensate bypass IN007 Rev N 0419 3 Saber Way, Ward Hill, MA 01835 | radonaway.com...
  • Page 7 Warranty RadonAway ® warrants that the HS Series Fan (the “Fan”) will be free from defects in materials and workmanship for a period of 90 days from the date of purchase (the “Warranty Term”). RadonAway ® will repair or replace any Fan which fails due to defects in materials or workmanship during the Warranty Term. The Fan must be returned (at Owner’s cost) to the RadonAway...

This manual is also suitable for:

Hs2000Hs3000Hs5000Hs2000eHs3000eHs5000e ... Show all