Steril-Aire 8100PVAB Installation And Operation Manual

Uvc controller

Advertisement

Installation and Operation Manual
Improper installation, adjustments, alterations, service,
maintenance, or use can cause fire, electrical shock,
personal injury or property damage. Consult your supplier
or Steril-Aire for information or assistance.
DANGER, WARNING, or CAUTION are universally used
for overall safety. DANGER identifies the most serious
hazards which will result in severe personal injury or
death. WARNING signifies hazards which could result in
personal injury or death. CAUTION is used to identify
unsafe practices resulting in minor personal injury or
product and property damage.
WARNING:
Before performing maintenance,
ensure unit is unplugged. Electrical shock can cause
death.
CAUTIONS:
 Never expose eyes or skin to UVC light. Wear
gloves, face shield/glasses (per ANSI Z87.1) and
cover all exposed skin.
I
C
MPORTANT
ONSIDERATIONS
UL File Number E841436
Patents: 5,334,347/ 5,817,276/ 5,866,076/ 6,245,293/ 6,267,924/ 6,280,686/
6,313,470/ 6,372,186/ 6,423,882/ 6,500,267 /6,589,476/ 6,627,000/
6,783,578/7,140,749/ 7,282,728/ 7,459,694 & others pending
NOTE: Read the entire manual
before starting the installation.
 Do not touch Emitter
Damage to Emitter may result.
fingerprints will permanently etch glass of
Emitter and weaken structure.
using a Steril-Aire cleaning kit (included).
Isopropyl alcohol and a lint-free wipe may be
substituted.
 UVC Emitters are fragile. Handle UVC Emitter
with care.
 Voltages outside of the range designed for the
unit will void the warranty and do permanent
damage to the entire unit.
 Emitters contain mercury. If an Emitter breaks,
clean and dispose of with the same care as a
fluorescent lamp.
 UVC
energy
can
components. Protect such components with UV
resistant material such as aluminum foil,
aluminum duct tape, metallic shields, etc.
 The qualified installer or agency must use
factory kits and accessories when installing this
product.
UVC Controller
MODEL: 8100PVAB
100/120/208/240VAC
40A 9.6KW MAX
UL Approved
Made in the USA
TM
glass without gloves.
Oil from
Clean Emitter
damage
non-metallic

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 8100PVAB and is the answer not in the manual?

Questions and answers

Summary of Contents for Steril-Aire 8100PVAB

  • Page 1 Damage to Emitter may result. Oil from personal injury or property damage. Consult your supplier fingerprints will permanently etch glass of or Steril-Aire for information or assistance. Emitter and weaken structure. Clean Emitter using a Steril-Aire cleaning kit (included). DANGER, WARNING, or CAUTION are universally used Isopropyl alcohol and a lint-free wipe may be for overall safety.
  • Page 2: Installation

    NSTALLATION Ensure mains at the power panel are turned off before connecting power to the controller. Apply any necessary protection to assure that mains are not accidently turned on during the installation. 1) Make sure all the circuit breakers in the watchdog operation.
  • Page 3 Connection/component Locations Line output fuse, PN:80004125-500 Line output fuse, low voltage circuit, PN:80004115-1000 TB2 Ground Bar Door Switch Connection Circuit Breakers Door Switch Connection Watchdog connection to BMS (dry contacts) Watchdog Reset Display...
  • Page 4: Reading The Display

    Replace Emitters. the end of their useful lifespan. The 9,000-hour timer runs only when power is applied to the No Alarm emitters. Replace with authentic Steril-Aire emitters for maximum output and lifespan. Blinks once  Bank 1 Blink every second.
  • Page 5: Maintenance

    AINTENANCE Emitters need to be replaced every 9000 hours. Use Genuine Steril-Aire Emitters to maintain design output. If a Steril-Aire UVC Radiometer Kit is used, the Emitters should be replaced when the output falls below 50% of initial output. PARE OR...