Installation and Operation Instructions
NOTE: Read this entire instruction sheet before starting the installation.
Improper installation, adjustment, alteration, service,
maintenance, or use can cause fire, electrical shock, or
other conditions which may cause personal injury or
property damage. Consult your supplier or Steril-Aire for
information or assistance.
Understand the signal words DANGER, WARNING, or
CAUTION. These words are universally used for overall
safety. DANGER identifies the most serious hazards
which will result in severe personal injury or death.
WARNING signifies hazards which could result in
personal injury or death. CAUTION is used to identify
unsafe practices resulting in minor personal injury or
product and property damage.
WARNING:
Before performing maintenance or
service on fixture, ensure unit is unplugged.
Electrical shock can cause injury or death.
CAUTIONS:
Never expose eyes or skin to UVC light.
Wear gloves, face shield/glasses (per ANSI
Z87.1) and cover all exposed skin.
Do not touch Emitter
Damage to Emitter may result.
fingerprints will permanently etch glass of
Emitter and weaken structure. If necessary,
clean Emitter using a Steril-Aire cleaning kit,
Patents 6,297,924/ 6,280,686/ 6,313,470/ 6,372,186/ 6,423,882/ 6,500,267/ 6,589,476/
6,627,000/ 6,783,578/ 7,140,749/7,282,728/ 7,459,694 & others pending
I
MPORTANT
TM
glass without gloves.
Oil from
ENHANCED SINGLE ENDED
FIXTURE, 24" – 61" EGTS
Part Number 11003000
C
ONSIDERATIONS
isopropyl alcohol and a lint-free wipe may be
substituted.
UVC Emitters are fragile.
accidental breakage, handle the UVC Emitter
with care.
Voltages outside of the range designed for
the unit will void the warranty and do
permanent damage to the entire unit.
Emitter contains a small quantity of mercury.
If an Emitter breaks, clean and dispose with
the same care as a fluorescent lamp.
UVC energy may cause damage to non-
metallic components.
shall be protected with UV resistant material
such as aluminum foil, aluminum duct tape,
metallic shields, etc.
The qualified installer or agency must use
factory kits and accessories when installing
this product.
Once the installation is complete, the UVC fixture
should be operated continuously to preclude the
development of mold and bacteria.
recommended to cycle the Emitters by time clock or
fan operation.
ESE 1 SERIES
120-277 V
Made in the USA
To prevent
Such components
It is not

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ESE 1 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Steril-Aire ESE 1 Series

  • Page 1 • other conditions which may cause personal injury or UVC Emitters are fragile. To prevent property damage. Consult your supplier or Steril-Aire for accidental breakage, handle the UVC Emitter information or assistance. with care. • Voltages outside of the range designed for...
  • Page 2 & O NSTALLATION PERATION NOTE: ENSURE THAT EMITTER IS INSTALLED BEFORE POWER IS APPLIED. INSTALLING EMITTER AFTER 9. Using the fixture base as a template scribe and POWER HAS BEEN APPLIED MAY TRIGGER THE “END- then create an insertion hole, 2” diameter where OF-LAMP-LIFE CIRCUIT”...
  • Page 3 ROUBLESHOOTING Symptom Possible Causes Corrective Action Emitter does not light Cover Off/interlock switch open Install cover/depress interlock switch Momentary loss of power. Reset Power Turn off power for 10 Seconds, and then turn power on. Poor connection Check connection to emitter. Check wiring connections.
  • Page 4 90000100 _________________________________________________________________________________________________ Thank you for choosing Steril-Aire, #1 “UVC for HVAC” solution provider worldwide. Please contact your local supplier or Steril-Aire directly if we can provide any further information or service. Call 1-818-565-1128 or visit www.steril-aire.com. Your satisfaction is very important to us.

This manual is also suitable for:

11003000

Table of Contents