APPENDIX A : INVERTER SETTINGS
02:Digital input / output Parameters.
Pr. No.
02-00
Two-wire / three-wire operation control.
02-03
Multi-function input command 3 (MI3)
02-04
Multi-function input command 4 (MI4)
02-13
Multi-function output 1 (RY1)
02-16
Multi-function output 2 (MO1)
05:Motor Parameters.
Pr. No.
05-01
Motor parameter auto-truing
05-03
Rated speed for induction motor 1 (rpm)
05-04
Number of poles for induction motor 1
05-05
No-load current for induction motor 1(A)
06:Protection Parameters (1)
Pr. No.
Over-Torque detection selection
06-06
(motor 1)
06-07
Over-Torque detection level (motor 1)
06-08
Over-Torque detection time (motor 1)
Electronic thermal relay selection
06-13
(motor1)
Electronic thermal relay action time
06-14
motor1)
07:Special Parameters.
Pr. No.
07-19
Fan cooling control
Motor specifications︰1/2HP, 3PH 220/380V 60Hz 1.9/1.10A 1730RPM 4P
Line speed:60~1200mm, Roller diameter:ψ200(628.4mm)1.90rpm/min
Parameters Function
Parameters Function
Parameters Function
Parameters Function
Explanation
2:Two-wire mode 2, power on for
operation control.
(M1:RUN/ STOP,M2:REV/FWD)
6:Zero speed including stop (Frequency
command)
5:Zero speed (Frequency command)
11:Malfunction indication
1:Indication during RUN
Explanation
Depending on the model power
Depending on the model power
Depending on the model number of poles
Depending on the model power
Explanation
3:Continue operation after over-torque
decoction during run)
0~250% (100% corresponds to the
current of the drive)
0.0~60.0 sec
0:Inverter motor (with extremal forced
Colling)
1:Standard motor (motor with fan on
the shaft)
30.0~060.0sec
Explanation
Fan is always ON
17
Setting
Value
2
6
5
11
1
Setting
Value
1.9
1730
4
1.12
Setting
Value
3
150
1
0
60
Setting
Value
0