installation
Electrical diagram
For increased safety, ask a qualifi ed technician to perform a
thorough check of the electrical system.
The manufacturer is not responsible for any damage caused by the
lack of a suitable earthing system or by the malfunctioning of the
electricity mains supply.
Peripheral unit
T
B
BUS
TA2
SE
CN9
HV connection
LV connection
Display
C.H. Return
temp. probe
Bl
C.H. Flow
temp. probe
Flue
thermostat
Minimum water
pressure switch
20
TNK
SOL TA1
N
L
1
N
L
FLAME
N
N
FLAME
Bl
Rd
Rd
Br
Br
Bk
Br
1
L
L
CN14
CN3
CN9
CN25
CN8
GENUS PREMIUM EVOHP 45/65
Gr
Detection electrode
Fan
Wh
Rd
Bk
Bk
Br
Bl
Bk
Bk
Bk
Bk
Circulation Pump
Ignitor
Gas valve
Diverter valve

Advertisement