UNIGATE
INVERTER
(1I - 2I - 1I BIG - 2I BIG)
UNIGATE
24V
UNIGATE
BR (36V)
SEA USA Inc.
10850 N.W. - 21st - unit 160 - Doral - MIAMI
Florida (FL) - 33172 - USA
Telephone
: ++1-305.594.1151
-
++1-305.594.7325
Toll free:
800.689.4716
www.sea-usa.com
sales@sea-usa.com
67412089
REV. 01 - 03/2022

Advertisement

loading
Need help?

Need help?

Do you have a question about the UNIGATE INVERTER 1I and is the answer not in the manual?

Questions and answers

Summary of Contents for SEA USA UNIGATE INVERTER 1I

  • Page 1 UNIGATE INVERTER (1I - 2I - 1I BIG - 2I BIG) UNIGATE UNIGATE BR (36V) SEA USA Inc. 10850 N.W. - 21st - unit 160 - Doral - MIAMI Florida (FL) - 33172 - USA Telephone : ++1-305.594.1151 ++1-305.594.7325 Toll free: 800.689.4716...
  • Page 2 INDEX SAFETY INFORMATION AND «UL» STANDARDS REQUIREMENTS PRELIMINARY INFORMATION AND PRODUCT DETAILS 1 - CONNECTIONS ON THE «UNILOGIC» BASIC MODULE 2 - CONNECTIONS ON CN1 START, STOP , 24V , 10K , « » , « » 3 - CONNECTIONS ON CN2 , 24V «...
  • Page 3 INDEX 12 - CONNECTIONS ON CNB - EMERGENCY BATTERIES CONNECTIONS « » « » « » « » 13 - RECEIVERS CONNECTION ON CNR 14 - ADDITIONAL FUNCTIONS OF THE CONTROL UNIT «S » , E.F.O. 15 - DISPLAY OPERATION AND PROGRAMMING MENU 16 - BASIC MENU 17 - INPUTS STATUS MANAGEMENT N.C.
  • Page 4 IMPORTANT SAFETY INFORMATION GENERAL SAFETY PRECAUTIONS The following precautions are an integral and essential part of the product and must be supplied to the user; Read them carefully as they contain important indications for the safe installation, use and maintenance. 1.
  • Page 5 GENERAL SAFETY INFORMATION An appliance shall be provided with an instruction manual. The instruction manual shall give instructions for the installation, operation, and user maintenance of the appliance. The installation instructions shall specify the need for a grounding-type receptacle for connection to the supply and shall stress the importance of proper grounding.
  • Page 6 The installer shall follow the provided instructions thoroughly. SEA products must only be used to automate doors, gates and wings. Any initiative taken without SEA USA Inc. explicit authorization will preserve the manufacturer from whatsoever responsibility.
  • Page 7 NOTES: 1. The same type of device shall not be used for both entrapment protection means. Use of a single device to cover both the opening and closing directions is in accordance with the requirement; however, a single device is not required to cover both directions.
  • Page 8 PRELIMINARY UNIGATE «UNILOGIC» UNILOGIC UNIGATE 18); JOLLY 3 SEACLOUD JOLLY 3 SEACLOUD (FV) 03.12 00.04 00.28 TECHNICAL INFORMATION 230V - 50/60 H IP 55 30 mA -20° C +50°C 115V - 50/60 H IMPORTANT SAFETY INFORMATION - RESET BUTTON UNIGATE «...
  • Page 9 UNIGATE INVERTER - «FV» MODULE UNIGATE INVERTER 1I UNIGATE INVERTER 2I MANAGEMENT OF MANAGEMENT OF 2 OPERATORS WITH INVERTER 1 OPERATOR WITH INVERTER - - - - - - - - - - - - - - - - - - - - - - - -...
  • Page 10 UNIGATE 24V - «24V» MODULE UNIGATE 24V CONNECTIONS ON «24V» MODULE 1 or 2 24V OPERATORS MANAGEMENT CONNECTOR POWER TO «UNILOGIC» SUPPLY CONNECTOR - - - - - - - - - - - - - - - - «24V» MODULE - - - - - - - - - - - - - - - - DOWN...
  • Page 11 1 - CONNECTIONS ON «UNILOGIC» MODULE WARNING: CONNECT ALL DEVICES WHEN THE CONTROL UNIT IS SWITCHED-OFF ANT COM START STPD STOP COM PH1 PH2 EDGE1 EDGE2 COM AUX FL(-) DISPLAY 14 15 16 17 18 19 20 21 22 LSO1 LSC1 COM LSO2 LSC2 24V+ COMIS LOCK 23 24 25 26 27 28 29 30 +PG E1/D1 COM E2/D2 GP1 GP2 COM 24V...
  • Page 12 2 - CONNECTIONS ON CN1 2.1 - START (N.O.) « » » « 2.2 - PARTIAL START (N.O.) « » » « PARTIAL OPENING PARTIAL PAUSE 9 10 « » « » TRAFFIC LIGHT RESERVATION 2.3 - STOP (N.C.) « »...
  • Page 13 2.7 - 24V FLASHING LIGHT - MAX 3W EXAMPLE OF LAMP AND 12 ( CN2) SAFETY EDGE CONNECTION FLASHING AFETY EDGE LIGHT FLASHING AFETY 2.8 - SAFETY EDGE (N.C.) SAFETY SAFETY EDGE EDGE 100-101 102-103 EDGE EDGE DIRECTION DIRECTION NORMAL SAFETY EDGE XAMPLE EXAMPLE...
  • Page 14 2.11 - SAFETY LOOP EXAMPLE OF SAFETY LOOP CONNECTION 3 = S (N.O.) FREE EXIT LOOP 6 = C REVERSE LOOP 7 = P 1 (N.C.) SHADOW LOOP 14 15 16 17 18 19 20 21 22 24V COM 8 = P 2 (N.C.) LOOP 1 OUT 1 LOOP 2 OUT 2 LOOP 3 OUT 3...
  • Page 15 3 - CONNECTION ON CN2 3.1 - LIMIT SWITCH EXAMPLE OF LIMIT SWITCH CONNECTIONS 14 15 16 17 18 OPENING LIMIT SWITCH MOTOR 1 CLOSING LIMIT SWITCH ); I MOTOR 1 OPENING LIMIT SWITCH XAMPLE MOTOR 2 OPENING ANTI INTRUSION CLOSING CLOSING LIMIT SWITCH MOTOR 2...
  • Page 16 4 - CONNECTIONS ON CN3 4.1 - ENCODER CONNECTION BLUE WHITE BLUE WHITE CN3; BROWN BROWN 25 (29) 25 (29) BLACK GREEN BLACK GREEN 23 24 25 26 27 28 29 30 OLD MODEL BROWN WHITE GREEN NEW MODEL BLUE BLACK «ABC»...
  • Page 17 4.4 - «POSITION GATE» POTENTIOMETER CONFIGURATION POTENTIOMETER I. PAR. M1 I. PAR. M2 POTENTIOMETER I. AP. M1 I. AP. M2 DOWN POTENTIOMETER I. CH. M1 I. CH. M2 DOWN « » 22); 4.5 - «POSITION GATE» POTENTIOMETER PARAMETERS ADJUSTMENT M1 OPENING M1 CLOSING M2 OPENING M2 CLOSING...
  • Page 18 4.7 - «GP1» e «GP2» PROGRAMMABLE INPUTS «GP1» «GP2» GP1 (27) = PROGRAMMABLE INPUT ( . . 23 24 25 26 27 28 29 30 GP2 (28) = PROGRAMMABLE INPUT 4.8 - TEMPERATURE PROBE CONNECTION REMOVE GP1 ( COM ( CLAMP CLAMP THE OIL...
  • Page 19 5 - SPECIAL CONNECTIONS ON CN2 and CN3 5.1 - «BIG FAST» OPERATOR LIMIT SWITCH CONNECTION 1 «BIG FAST» OPERTOR, 2 «BIG FAST» OPERTORS, 14 15 16 17 18 23 24 25 26 27 28 29 30 MOTOR 2 «SLOWDOWN LIMIT SWITCH» MOTOR OPENING LIMIT SWITCH MOTOR...
  • Page 20 6 - CONNECTION ON CLS 6.1 - LIMIT SWITCH CONNECTION ON THE «CLS» QUICK CONNECTOR XAMPLE OF OPERATOR WITH A PRE WIRED LIMIT SWITCH 7 - CONNECTIONS ON CR1 and CR2 7.1 - RELAY 1 and RELAY 2 MANAGEMENT COM1 NO1 NC1 COM1 NO1 NC1 START RELAY 1...
  • Page 21 7.4 - ELECTRIC VALVE CONNECTION VIA RELAY POWER SUPPLY LECTRIC VALVE 230V/115V/24V/12V (*) COM1 NO1 NC1 OPENING ELECTRIC NEUTRAL RELAY 1 VALVE XAMPLE LINE LINE 7.5 - TRAFFIC LIGHT CONNECTION VIA RELAY SEMPI ENTRANCE EXIT TRAFFIC TRAFFIC RELAY 1 RELAY 2 LIGHT LIGHT TRAFFIC LIGHT...
  • Page 22 8 - CONNECTION ON P/S (only for «FV» and «BR» modules) 8.1 - «PRIMARY/SECONDARY» (MASTER/SLAVE) CIRCUIT « » « » PRIMARY SECONDARY « » « » 1-LANGUAGE 47-MOTOR 1 PARTIAL ENCODER 83-EXTRA TIME 86-FLASHING LIGHT 3-MOTOR 48-MOTOR 1 TOTAL ENCODER 88-COURTESY LIGHT 59-MOTOR 1 SLOWDOWN IN OPENING 5-REVERSE MOTOR...
  • Page 23 9 - CONNECTION ON EXP 9.1 - RS 485 CIRCUIT RS 485 RS 485 XAMPLE UNILOGIC CONNECTIONS ON ONE OR TWO OPERATORS (JOINT BIG FAST) MOTOR 2 MOTOR 1 CONNECTION CONNECTION 1 = RED 2 = WHITE 3 = BLACK 4 = YELLOW CIRCUIT RS 485...
  • Page 24 10 - MOTORS WIRINGS 10.1 - OPERATORS WIRING ON «FV» MODULE UNIGATE - 1I UNIGATE - 2I MOTOR 1 (115V) MOTOR 2 (115V) CONNECTOR CONNECTOR = BLACK = BLACK ON THE FIRST ON THE SECOND = WHITE = WHITE «FV» MODULE «FV»...
  • Page 25 10.3 - OPERATORS WIRING ON «24V» MODULE UNIGATE 24V MOTOR 1 (24V) MOTOR 1 (24V) = RED (BROWN) = RED (BROWN) = BLACK (BLUE) = BLACK (BLUE) 10.4 - OPERATORS WIRING ON «BR» MODULE UNIGATE BR UNIGATE 2BR CONNECTOR CONNECTOR ON THE FIRST ON THE SECOND MOTOR 1 (36V)
  • Page 26 11 - POWER SUPPLY 11.1 - «UNILOGIC» MODULE POWER SUPPLY MAIN TERMINAL SWITCHING 16AT 230V~ POWER SUPPLY ON «UNILOGIC» 16AT 115V~ BLACK WHITE GREEN XAMPLE OF WITCHING .800VA BLACK 11.2 - «FV» MODULE POWER SUPPLY «FV» «FV» POWER TERMINAL ON «UNILOGIC»...
  • Page 27 12 - CONNECTION ON CNB 12.1 - «STAR 400/800» EMERGENCY UPS CONNECTION «STAR 400/800» «FV» UNILOGIC EMERGENCY XAMPLE LAST EMERGENCY OPENING STAR 400-800 TERMINALS ON SWITCHING BATTERY PACK UNILOGIC «PW» «CNB» STAR 400/800 12.2 - EMERGENCY BATTERIES ON «UNIGATE BR» SWITCHING TERMINALS ON TERMINALS...
  • Page 28 13 - RECEIVERS CONNECTION ON CNR and FIX RF UNI « » RF UNI PG RF FIX 14 - ADDITIONAL FUNTIONS 14.1 - DATE/TIME FUNCTION TO PROGRAM THE OPENINGS Example SET THE TIME SET THE DAY SET THE DATE OF THE WEEK MONTH YEAR 08:00...
  • Page 29 14.3 - AMPEROMETRIC MANAGEMENT - ONLY FOR 24V and «BR» ELECTROMECHANIC OPERATORS OFF ( SPECIAL MENU SLOWDOWN LANGUAGE OP. SPEED SPECIAL MENU SENSITIVITY DOWN XAMPLE M1 OPENING M1 CLOSING M2 OPENING M2 CLOSING TORQUE TORQUE TORQUE TORQUE DOWN M1 OPENING M1 CLOSING M2 OPENING M2 CLOSING...
  • Page 30 OUTPUT 14.6 - «I/O SURGE PROTECTOR» CIRCUIT CONNECTION CONNECTION ON CONTROL UNIT 24V DC ACCESSORIES GROUNDING CONTACT 1 (Es. PHOTOCELL) CONTACT 2 (Es. SAFETY EDGE) CONTACT 3 (Es. START) OUTPUT CONTACT 4 24VDC CONTACT 5 CONTACT 6 INPUT ACCESSORIES CONNECTION 24V DC ACCESSORIES CONTACT 1 (Es.
  • Page 31 15 - DISPLAY and PROGRAMMING CONNECT ALL THE ACCESSORIES WHEN THE CONTROL UNIT IS SWITCHED OFF! AFTER ALL CONNECTIONS HAVE BEEN MADE, POWER ON THE UNIT FOR SETTINGS 15.1 - POWER ON THE CONTROL UNIT SOFTWARE INPUTS STATUS BASIC REVISION (CHAPTER 17) MENU Power ON...
  • Page 32 15 - SCHEMA FUNZIONI MENU DI BASE 16 - BASIC MENU MOVE BY PRESS TO CONFIRM AND RETURN TO ENGLISH LANGUAGE THE MAIN MENU DOWN SKIP THIS STEP IF YOU DO NOT NEED TO PROGRAM THE TX CONFIRM AND EXIT READ THE CHAPTER 21 PRESS ON THE TX PRESS...
  • Page 33 17 - INPUTS STATUS MANAGEMENT (0) - N.O. - N.C. - START (**) MOTOR 1 OPENING LIMIT SWITCH 1 2 3 4 5 6 7 8 PARTIAL START MOTOR 1 CLOSING LIMIT SWITCH STOP MOTOR 2 OPENING LIMIT SWITCH PHOTOCELL 1 MOTOR 2 CLOSING LIMIT SWITCH 0 0 11111 0 PHOTOCELL 2...
  • Page 34 17.2 - INPUTS MANAGEMENT MENU HIS MENU ALLOWS TO ENABLE OR DISABLE THE INPUTS WITHOUT REPEATING THE WORKING TIMES LEARNING LANGUAGE HOLD PRESSED 5 SECONDS START ENABLED START RETURN START DISABLED DOWN PARTIAL ENABLED START PARTIAL RETURN START PARTIAL DISABLED START DOWN STOP...
  • Page 35 18 - WORKING TIMES LEARNING DANGER! AVE A QUALIFIED SERVICE PERSON TO CARRY OUT THE OPERATIONS IN SAFE CONDITIONS 18.1 - QUICK START - ONLY FOR SLIDING OPERATORS OWER 0 0 11111 0 11111111 HOLD PRESSED 5 SECONDS CLOSE-OPEN-CLOSE 18.7 18.2 - WORKING TIMES LEARNING BY LIMIT SWITCH INPUT MANAGEMENT MENU 18.7...
  • Page 36 18.5 - WORKING TIMES LEARNING BY PULSES DETECTION - WITH POTENTIOMETER 18.4 18.7, « » DOWN XAMPLE DURING THE LEARNING CYCLE, PRESS PROGRAM- «UP» ON THE DESIRED STOP POINTS MING XAMPLE 18.6 - WORKING TIMES LEARNING BY PULSES DETECTION - WITHOUT POTENTIOMETER SPECIAL MENU...
  • Page 37 19 - LOGICS « », SEMI-AUTOMATIC LOGIC: PAUSE «OFF» ( TIME : START START AUTOMATIC LOGIC: AUTOMATIC LOGIC XAMPLE PAUSE SECONDS TIME START START IN PAUSE : START START ; START SAFETY LOGIC: START SAFETY START LOGIC START STEP BY STEP TYPE 1: START OPEN-STOP CLOSE-STOP...
  • Page 38 21 - RECEIVERS AND TRANSMITTERS START ALWAYS ROLLING CODE, ROLLING CODE; 21.1 - OLD «ROLLING CODE» CODING PRESS TWICE! PRESS TWICE ONLY PRESS TO STORE THE FIRST STORED START LANGUAGE TRANSMITTERS BUTTON KEY ON THE FIRST TX PRESS ONCE XAMPLE PRESS ONCE TO STORE THE SECOND KEY AND PARTIAL...
  • Page 39 21.4 - TRANSMITTERS FUNCTIONS DIAGRAM T H E « S T A R T » COMMAND MUST ALWAYS PRESS STORED START BE STORED ON THE FIRST LANGUAGE TRANSMITTERS BUTTON TX CHANNEL PRESS THE BUTTON TO STORE SETTING OF THE PARTIAL START PARTIAL PRESS STORED...
  • Page 40 22 - ALARMS 22.1 - FAULTS SHOWN ON THE DISPLAY XAMPLE SAFETY ESCE EDGE 1 FAULT WARNING MESSAGE SOLUTION NETWORK FAULT HECK THE PRESENCE OF THE POWER SUPPLY HECK THE FUSE FAULT 24 HECK FOR ANY OVERLOADS OR SHORT CIRCUITS ON THE WIRING OR ON THE CONTROL UNIT FAULT COMIS HECK THE OPERATION OF COMIS CONTACT AND THE ACCESSORIES WIRING ON THE CONTROL UNIT SAFETY EDGE 1 FAULT...
  • Page 41 22.3 - FAULTS SIGNALED ON THE FLASHING LIGHT «S » ALARM TYPE NUMBER OF FLASHES NOTES COMIS FAST EVERY TIMES OMIS FAULT CHECK WIRINGS INVERTER 1 FAULT EPAIR OR REPLACEMENT NEEDED SLOW EVERY TIMES INVERTER 2 FAULT SLOW EVERY TIMES EPAIR OR REPLACEMENT NEEDED REPORT PHOTO 1 - 2 IN CLOSING SLOW...
  • Page 42 23 - TROUBLESHOOTING «ON»...
  • Page 44 MENU FUNCTIONS TABLE - UNIGATE LEGEND INVERTER - FUNCTION AVAILABLE ON MODEL UNIGATE WITH "FV" INVERTER MODULE (1I - 2I - 1I BIG - 2I BIG) 24V - FUNCTION AVAILABLE ON MODEL UNIGATE WITH 24V MODULE BR - FUNCTION AVAILABLE ON MODEL UNIGATE WITH BR MODULE ALL - COMMON FUNCTIONS - AVAILABLE ON ALL UNIGATE MODELS MENU DESCRIPTION...
  • Page 45 MENU DESCRIPTION MODEL DEFAULT NOTE 32- ORION BOX FAST 24Vdc electromechanic operator 35- SURF 24Vdc electromechanic operator SURF 39- HT 270/390 24VDC 24Vdc hydraulic operator 43- SURF FAST 24Vdc electromechanic operator 65 KITE LS 24Vdc electromechanic operator 50- HALF TANK BR Hydraulic operator - Series BR (BRUSHLESS) 3 MOTOR 51- SURF BR...
  • Page 46 MENU DESCRIPTION MODEL DEFAULT NOTE A count-down of 5 seconds will start by holding the UP button; at its end "INIT" will appear on the display as 14 RESET confirmation of the control board reset Allows the movement of the gate in a temporary "dead man" mode INVERTER (for example to test the correct running of the motor) 192 MOVE GATE 1 *...
  • Page 47 SPECIAL MENU PRESS AT THE SAME TIME FOR 5 SECONDS TO ENTER OR TO EXIT THE SPECIAL MENU LEGEND INVERTER - FUNCTION AVAILABLE ON MODEL UNIGATE WITH "FV" INVERTER MODULE (1I - 2I - 1I BIG - 2I BIG) 24V - FUNCTION AVAILABLE ON MODEL UNIGATE WITH 24V MODULE BR - FUNCTION AVAILABLE ON MODEL UNIGATE WITH BR MODULE ALL - COMMON FUNCTIONS - AVAILABLE ON ALL UNIGATE MODELS SPECIAL MENU...
  • Page 48 SPECIAL MENU DESCRIPTION MODEL DEFAULT NOTE ON = Encoder enabled OFF = Encoder disabled depends on motor (when OFF, the working times learnt are only shown) 32 ENCODER To enable the rotary Encoder for the management of Enc ABC depends the brushless operator and its position on motor 47 ENCODER PAR.1...
  • Page 49 SPECIAL MENU DESCRIPTION MODEL DEFAULT NOTE 10% (Fast intervention) To adjust the amperometric sensitivity in slowdown 99% (Slow intervention) Function available only on electro-mechanic operators SLOWDOWN SENSITIVITY MOTOR To set the inversion time in slow-down from 0 to 5 With potentiometer seconds (= 99%) - Only with potentiometer enabled POTENTIOMETER 1 THRESHOLD...
  • Page 50 SPECIAL MENU DESCRIPTION MODEL DEFAULT NOTE To disable the anti-overlapping control of the leaves allowing their separate control 69 ANTI OVERLAP To enable the anti-overlapping control of the leaves OPENING POSITION To retrieve the inertia of the motor in opening after the 20 seconds depends RECOVERY...
  • Page 51 SPECIAL MENU DESCRIPTION MODEL DEFAULT NOTE Normal Normal Light Warning lamp function 86 FLASHING LIGHT Normal Always Always ON Buzzer Buzzer The flashing light will be OFF with enabled timer and open gate FLASHING LIGHT AND TIMER The flashing light will be ON with enabled timer and open gate Disabled 88 COURTESY LIGHT...
  • Page 52 SPECIAL MENU DESCRIPTION MODEL DEFAULT NOTE Photo 1 Self-test enabled only on photocell 1 Photo 2 Self-test enabled only on photocell 2 95 PHOTO-TEST Photo 1 and 2 Self-test enabled on photocells 1 and 2 Disabled Edge 1 Self-test enabled only on safety edge 1 Edge 2 Self-test enabled only on safety edge 2 SAFETY EDGE...
  • Page 53 SPECIAL MENU DESCRIPTION MODEL DEFAULT NOTE If the photocell is occupied during closing, the gate Closing reverses the movement; If the photocell is occupied during the pause, it prevents the gate reclosing If the photocell is occupied during opening or closing, it Opening and closing stops the gate movement;...
  • Page 54 SPECIAL MENU DESCRIPTION MODEL DEFAULT NOTE Normal Normal N.C. contact 8K2 N.C. Safety edge protected by a 8K2 resistor enabled SAFETY EDGE 2 Normal 8K2 N.C. Double Two safety edges protected by 8K2 resistor enabled 8K2 RES Resistive edge protected by 8K2 resistor enabled 8K2 RES Double Two resistive edges protected by 8K2 RES enabled Opening and closing...
  • Page 55 SPECIAL MENU DESCRIPTION MODEL DEFAULT NOTE Disabled In case of power failure and with batteries connected Emergency and charged, the gate opens completely and remains open until the power is restored In case of power failure, as soon as the battery charge EMERGENCY Last opening drops below 22V, the gate opens one last time and...
  • Page 56 SPECIAL MENU DESCRIPTION MODEL DEFAULT NOTE To set a second time band in which keeping the gate Opening time open. It is possible to set, in order: opening time, closing Closing time time and the days on which you want to open and keep 125 CLOCK 2 the gate open Days...
  • Page 57 SPECIAL MENU DESCRIPTION MODEL DEFAULT NOTE Disabled To enable the Relay 1 for 3 seconds at every Start or Start 3s reopening command Traffic light management: the green light is switched-on Traffic light 1 only when the gate is open By a Start command the traffic light in entrance turns green and the access priority is acquired while the Traffic light in entrance...
  • Page 58 SPECIAL MENU DESCRIPTION MODEL DEFAULT NOTE Disabled To enable the Relay 2 for 3 seconds at every Start or Start 3s reopening command Traffic light management: the green light is switched-on Traffic light 1 only when the gate is open By a Start command the traffic light in entrance turns green and the access priority is acquired while the Traffic light in entrance...
  • Page 59 SPECIAL MENU DESCRIPTION MODEL DEFAULT NOTE Disabled Positive brake Positive electric-brake (The relay FV1 will be ON only management with stopped gate) Negative electric-brake (The relay FV1 will be ON only Negative brake during operator cycle, 1 second before start and in management case of photocell intervention ) RELAY FV 1...
  • Page 60 SPECIAL MENU DESCRIPTION MODEL DEFAULT NOTE Adjusts the amperometric intervention threshold of THRESHOLD A depends 10 Ampere motor 1 in opening (over the set threshold motor will INVERTER OPENING 1 detect an obstacle) motor Adjusts the amperometric intervention threshold of THRESHOLD A depends 10 Ampere...
  • Page 61 No indemnities are recognized during repairing and/or replacing of the products under warranty. SEA USA Inc. and SEA S.p.A. decline any responsibility for damages to person and objects deriving from non-compliance with safety standards, installation instructions or use of the products sold. It is intended that warranty will be recognized only on products bought through the SEA authorized network.
  • Page 62 NOTES...
  • Page 63 NOTES...
  • Page 64 SEA USA Inc. 10850 N.W. 21st - unit 160 - DORAL - MIAMI Florida (FL) 33172 Phone: ++1-305.594.1151 Toll Free: 800.689.4716 www.sea-usa.com sales@sea-usa.com...