Power On Self Check Result Display - Panasonic HC-X900MP Service Manual

High definition video camera
Table of Contents

Advertisement

Indication contents
• Lock search history indication
Display the camera system error cord for three histories saved in EEPROM.
• The error cord contents which are displayed
Touch the [BAK] of LCD to end the service mode, and then POWER OFF.
6.3.

Power ON Self Check Result Display

Touch the [ 5 ] of LCD, select Power ON self check result display.
Operation specifications
Indication contents
• Power ON self check result display
Function to diagnose correct function of the device and interface between devices result display.
Display the following communication test result.
-CAM-PWR : Communication test between IC3401 to IC2304
-CAM-UNI : IC3401 internal communication test.
Display other than "OK" are abnormalities of each lines.
Cutting of battery connection or AC power supply connection to end the service mode.
Error
51
Focus control is abnormal
52
Zoom control is abnormal
53
OIS lens control is abnormal
71
Lens cover open/close is abnormal
72
Cooling fan is abnormal
73
High temperature is abnormal
code Function
20