6.3.

Power ON Self Check Result Display

Touch the [ 5 ] of LCD, select Power ON self check result display.
Operation specifications
Indication contents
• Power ON self check result display
Function to diagnose correct function of the device and interface between devices result display.
Display the following commnucation test result.
- CAM-PWR : Commnucation test between IC2006 to IC1503
- CAM-UNI : Commnucation test between IC2006 to IC3401
Display other than "OK" are abnomalities of each lines.
Cutting of battery connection or AC power supply connection to end the service mode.
6.4.

Forced full flash emission

Touch the [ 9 ] of LCD, select Forced full flash execution.
Operation specifications
Indication contents
• Discharging the capacitor without using register.
Forced full flash emission for charge capacitor completely discharge.
To prevent electric shock, we recommend enforcement before disassembling.
Press the power button and turn off.
19