1
A
ASMAX check
ASMAX value shows the value of RF level.
Status: [Foucs closed] of TEST MODE
No.
1
2
B
In this case, the value is displayed for a split second.
When you tried to perform [FOCS CLOSE],
C
the display will charge automatically in the following order.
[1FFF0000]->[FEMAX]->[FE MIN]->[AS MAX]->
[ENV MAX]->[FE normal]->[Spindle gain]->
[TEMAX]->[TEMIN]
Watch carefully the value of ASMAX.
Error rate check
Status: [Tracking Closed] of TEST MODE
No.
D
1
2
3
E
F
26
1
2
Disc
Check Point
8 digits value of
ASMAX
GGV1025
on display
8 digits value of
TCD-782
ASMAX
on display
->[20000000]
Disc
Check Point
GGV1025
ID: 40000
GGV1025
ID: 200000
TCD-782 ID: HOME Position
DVH-335UB/XNRC
2
3
Threshold
Remarks:
Only four last digits are
more than
displayed according to
0000 0B00
the product.
Only four last digits is
more than
displayed according to
the product.
0000 0C00
Threshold
Remarks:
less than
1.000E-03
less than
1.000E-03
less than
2.500E-03
3
4
4