Velocity SmokeWatch VDOT-U5015 Manual

Explosion proof smoke detector

Advertisement

Quick Links

WARNING
Be sure to read and understand the entire instruction manual
before installing or operating the smoke detection system. Any
deviation from the recommendations in this manual may impair
system performance and compromise safety.
OVERVIEW
The SmokeWatch™ VDOT-U5015 Explosion Proof Smoke Detector
has Division and Zone explosion-proof ratings and is suitable for
industrial and commercial applications. The detector is designed to
operate effectively with smoldering and rapidly growing fires and
contains the ability to annunciate fault ensuring no undisclosed
failures. The SmokeWatch VDOT-U5015 Smoke Detector outputs
include 0-20 mA, a localized LED, and relays.
Typical applications that use the U5015 include:
Combustible storage facilities
Munitions manufacturing
Volatile chemical storage
Chemical processing plants
Petroleum refineries
Turbine enclosures
Battery rooms
HVAC applications
The hot-swappable sensor module is intrinsically safe and allows live
maintenance while under power, without de-classifying the
hazardous area.
The integrated junction box is available in a variety of port
configurations for simplified wiring and installation.
See Figure 1 for all the U5015 Smoke Detector components.
FEATURES
FM Approved for use in Class I, Division 1 hazardous
locations
FM Approved for smoke detection performance
IECEx Zone approved
Trouble-free photoelectric operation
0-20 mA output for DCS integration
Self-checking circuitry ensures reliable smoke detection
Alarm, Auxiliary, and Fault relays for controlling
LED provides a visual indication that an alarm has occurred
IP44 ingress protection level suitable for onshore or
offshore requirements
BENEFITS
Ideally suited for classified areas in the petrochemical, oil,
and gas industry
DCS, PLC, integration with milliamp or relay outputs
Rugged design for environmental extremes
Visual confirmation of detector alarm
Detects smoldering fires
No undisclosed failures
www.velocitydetection.com
VDOT-U5015 Explosion Proof Smoke Detector
Doc: GLT-311-7-1
Issue: 001
Date: 28/10/2020

Advertisement

Table of Contents
loading

Summary of Contents for Velocity SmokeWatch VDOT-U5015

  • Page 1 The SmokeWatch VDOT-U5015 Smoke Detector outputs include 0-20 mA, a localized LED, and relays. Typical applications that use the U5015 include: •...
  • Page 2 VDOT-U5015 Explosion Proof Smoke Detector WARRANTY PERIOD— 1 year. SPECIFICATIONS DIMENSIONS— OPERATING VOLTAGE— See Figure 2. 12-30 Vdc (24 Vdc nominal) CERTIFICATION— For complete approval details, refer to the appropriate Appendix: SMOKE DENSITY— 1.5% - 2.5% obscuration per foot. (4.9% - 8.2% obscuration per meter). POWER CONSUMPTION—...
  • Page 3 VDOT-U5015 Explosion Proof Smoke Detector The smoke alarm relay has a single set of terminals and normally NON-LATCHING open / normally closed contacts, and normally de-energized A detector configured for non-latching operation will check the alarm operation. status of the detector once every 10 seconds. Once smoke falls below the alarm threshold, the alarm annunciation will clear within 10 The fault relay has a single set of terminals and normally open seconds.
  • Page 4: Important Safety Notes

    VDOT-U5015 Explosion Proof Smoke Detector IMPORTANT SAFETY NOTES INSTALLATION WARNING CAUTION The wiring procedures in this manual are intended to ensure All entries must contain appropriately rated plugs or fittings. proper functioning of the device under normal conditions. It is required that each plug or fitting be wrench-tightened to However, because of the many variations in wiring codes and an appropriate installation torque and meet the minimum regulations, total compliance to these ordinances cannot be...
  • Page 5: Protection Against Moisture Damage

    VDOT-U5015 Explosion Proof Smoke Detector PROTECTION AGAINST MOISTURE DAMAGE MOUNTING LOCATION OPTIONS It is important to take proper precautions during installation to Ceiling Mount ensure that moisture will not come in contact with the electrical The U5015 is intended for surface mounting. It is normally mounted connections of the system.
  • Page 6: Wiring Procedure

    VDOT-U5015 Explosion Proof Smoke Detector The field wiring terminal connections are certified for a single wire in 2. Unscrew the retaining ring to gain access to the wiring terminals size from 0.2 to 2.5 mm2 (or two conductors with same cross section (see Figure 8), and complete the installation of the system conduit.
  • Page 7: Maintenance

    VDOT-U5015 Explosion Proof Smoke Detector MAINTENANCE WARNING To avoid a potential electrostatic discharge (ESD), do not wipe or rub the surface of the VDOT-U5015 sensor module. NOTE The VDOT-U5015 Smoke Detector contains no user serviceable components and should never be opened. The VDOT-U5015 wiring compartment is the only part of the smoke detector that should be opened by the user in the field.
  • Page 8 VDOT-U5015 Explosion Proof Smoke Detector www.velocitydetection.com Doc: GLT-311-7-1 Issue: 001 Date: 28/10/2020...
  • Page 9 VDOT-U5015 Explosion Proof Smoke Detector www.velocitydetection.com Doc: GLT-311-7-1 Issue: 001 Date: 28/10/2020...
  • Page 10 VDOT-U5015 Explosion Proof Smoke Detector www.velocitydetection.com Doc: GLT-311-7-1 Issue: 001 Date: 28/10/2020...
  • Page 11 NOTE Velocity Detection reserves the right to apply a service charge for repairing returned product damaged as a result of improper packaging. Return all equipment via transportation prepaid to the factory in the United Kingdom www.velocitydetection.com...
  • Page 12 VDOT-U5015 Explosion Proof Smoke Detector www.velocitydetection.com Doc: GLT-311-7-1 Issue: 001 Date: 28/10/2020...
  • Page 13 VDOT-U5015 Explosion Proof Smoke Detector www.velocitydetection.com Doc: GLT-311-7-1 Issue: 001 Date: 28/10/2020...
  • Page 14 VDOT-U5015 Explosion Proof Smoke Detector www.velocitydetection.com Doc: GLT-311-7-1 Issue: 001 Date: 28/10/2020...
  • Page 15 VDOT-U5015 Explosion Proof Smoke Detector www.velocitydetection.com Doc: GLT-311-7-1 Issue: 001 Date: 28/10/2020...

Table of Contents