Download Print this page

Pushbutton Installation - rba RBA2731-032-UG Installation, Operation And Maintenance Instructions

Advertisement

Pushbutton Installation

Note: fittings and tube should be kept clean, bagged and undamaged prior to installation.
Figure 2
1. Cut to fit length of 1/4" PE Tubing and remove any burrs or sharp edges. Ensure that the outside diameter is free from
score marks. Tube ends should be square.
2. Firmly and fully insert the Tubing end into the Push-In Fitting up to the Tube Stop located approximately 1/2" [13mm]
deep.
3. Pull on the fitted Tubing to ensure it is secure. Tube should not come free from the Fitting. Water test the connection
assembly prior to leaving the site to ensure there are no leaks.
4. Prior to disconnecting the Tube from the Fitting, ensure that the Water Line is depressurised. Push Collet Square
towards the Push-In Fitting Body and hold. While holding the Collet in, pull on the PE Tubing to remove from the Push-
In Fitting.
Note: This product should be installed, by suitably qualified persons, in a fit for purpose application, to suitable materials,
using suitable fixings and comply with any relevant codes. It should be inspected periodically for signs of wear and tear that
may affect performance or safety.
Dimensions are subject to manufacturer's tolerance of +/-10mm. Rough-in should be completed with each fixture.
Important: Installation Instructions are subject to change without notice. Please visit our websites for latest revision.
6 of 6
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
SYDNEY | MELBOURNE | BRISBANE | PERTH | AUCKLAND
Australia 1300 788 778 www.rba.com.au | New Zealand 0800 722 111 www.rbagroup.co.nz