Download Print this page

Installation; Cleaning And Maintenance; Spare Parts - rba RBA2731-032-UG Installation, Operation And Maintenance Instructions

Advertisement

Installation

1. Check rough-in drawings against supplied product.
2. Mount hanger bracket to wall. Hanger bracket MUST be securely anchored with fasteners sufficient to support 3 times
the weight of the water cooler.
3. Remove the bottom cover from the water cooler and set aside in a safe place. Place the screws in a safe place for re-use
in later stages of installation.
4. Hang the water cooler on the hanger bracket, ensuring the bracket tabs engage AND seat in the slots in the back of the
water cooler. Verify the Water Cooler is level, straight and plumb.
5. Anchor water cooler to wall at other mounting points in Base. If necessary, shim lower rear mounting points to level unit.
6. Thoroughly flush the supply line and then connect water supply to water cooler.
7. Make up trap waste connection.
8. Flush the supply line to remove all foreign debris.
9. Connect water supply to water cooler with 1/2" BSP
10. Turn on building water supply and check all connections for leaks.
11. Air within the water supply will cause an irregular bubbler outlet stream until purged out by incoming water. Covering the
bubbler with a clean cup [or similar object] is recommended when first activating water cooler. Depress push button until
steady water stream is achieved.
12. Adjust bubbler to the site requirements;
12a. If water flow requires adjustment, insert a slotted narrow blade screwdriver in the centre of the button actuator.
Turning clockwise will increase flow and turning counterclockwise will decrease flow.
12b. The water temperature can be adjusted using a slotted screwdriver in the cold water thermostat and turning
clockwise to make colder and counterclockwise to make warmer.
12c. Bubbler Stream – Bubbler can be rotated slightly to direct the stream backwards or forwards.
13. Plug water cooler into electrical outlet and make sure unit begins to function.
14. Assemble bottom cover to water cooler with screws furnished.
Cleaning & Maintenance
1. Motors have lifetime lubrication and do not require scheduled maintenance.
2. Excess dirt or poor ventilation will cause the compressor overload protector to turn the compressor off and it will cycle
on and off with no cold water coming out of bubbler. Periodically clean with vacuum cleaner, air hose or brush the
condenser fins and cabinet ventilation louvers. In environments where dirt and dust is more prevalent, clean more
frequently.
3. Periodically remove access panels and clean out in-line strainer.
4. Do NOT use harsh chemicals, abrasive or petroleum based cleaners. Use of these will void RBA warranty.
5. Exterior panels can be cleaned using mild household detergents or warm, soapy water. Extra care must be used cleaning
chrome plated items and mirror finished stainless steel. They can scratch easily and should only be cleaned using a
clean, soft cloth and mild soap with water or a mild glass cleaner

Spare Parts

RBA Code No.
Description
RBA7003-095-001
Valve Assembly
RBA7003-099-000
Pushbuttton
3 of 6
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
SYDNEY | MELBOURNE | BRISBANE | PERTH | AUCKLAND
Australia 1300 788 778 www.rba.com.au | New Zealand 0800 722 111 www.rbagroup.co.nz

Advertisement