Components Supplied by Others
40mm Trap
Stop valve
Electrical outlet
Mounting fixings

Hydraulic Requirements

Operating pressure:
200-500kPa
Inlet:
G1/2B
Outlet:
40mm BSP Waste
Water Temp:
4o - 32o
Provide 102mm minimum clear space on fixture sides to allow for proper ventilation through cabinet louvers.
Due to cold waste water, we recommend the trap supplied by installer be insulated to prevent excessive condensation.
Rough-in and Dimensions
Prior to roughing-in consult with local, state, and federal codes for proper mounting height. Installation to be done in
accordance with AS/NZS3500.1 and AS/NZS3500.2
470
235
235
FFL
Pipe Installation [with bottle filler option]
2 of 6
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
470
73
162
162
108
CL
TRAP OUTLET
TO SUIT 40mm WASTE
G1/2" INLET
34
201
146
SYDNEY | MELBOURNE | BRISBANE | PERTH | AUCKLAND
Australia 1300 788 778 www.rba.com.au | New Zealand 0800 722 111 www.rbagroup.co.nz
73
55
34
470