Page 1
QUICK START GUIDE BPM200 - Blood Pressure Monitor PLEASE READ ALL THE INSTRUCTIONS BEFORE USE Scan to download the full manual with language translations Scannez pour télécharger le manuel complet traduit en plusieurs langues Scannen, um die vollständige Gebrauchsanweisung mit Übersetzungen herunterzuladen...
Safety Information • This device is intended for adult use only. Do not use this device on children. • This device should not be used on any female who is, or is suspected of being, pregnant. Besides providing inaccurate readings, the effects of this device on the foetus are unknown.
Page 4
The device should not need to be calibrated within the first two years of use. • If you have any problems with this device, such as setting up, maintaining or using the device, please contact the Duronic Customer Care Team for assistance. •...
Components Included Cuff 22~36cm (Type BF applied part) Blood Pressure Monitor 1. Air Jack 4. USB External Power Supply 2. User/Set Button 5. Memory Button 3. Start/Stop Button 4*AAA Batteries Choice of Power Supply 1. Battery powered mode: 4*AAA batteries 2.
Page 7
Setting the Date, Time and Unit 1. When the monitor is off, press and hold down the ‘USER/SET’ button for 5 seconds. The ‘User 1’ icon will flash. 2. Press the ‘USER’ button to change the year. Scoll through the year using the ‘MEMORY’...
How to Use Fastening the Arm Cuff 1. Tie the cuff on your upper arm, then position the tube off-center toward the inner side of arm in line with the little finger. 2. The cuff should be snug but not too tight. You should be able to insert one finger between the cuff and your arm.
How to Take a Measurement 1. Ensure that the cuff is fitted properly on your arm. Press the ‘START/STOP’ button to turn on the monitor. The device will finish the whole measurement automatically. 2. The cuff will inflate. When fully inflated the cuff can feel slightly tight or uncomfortable.
Understanding the Result Systolic pressure (SYS): The highest level of your blood pressure – when your heart beats, it contracts to pump blood through your arteries. Diastolic pressure (DIA): The lowest level of your blood pressure – when your heart relaxes between beats.
Please tighten the cuff loose? The cuff leaks The airbag of the cuff is Replace with a new cuff broken Caution: If blood pressure still cannot be measured normally with the above method, please contact Duronic. Do not disassemble it by yourself.
Product Specifications Product Name Electronic Blood Pressure Monitor Model BPM200 Display Mode Digital Display Measuring Method Oscillographic Measuring Part Upper Arm 30mmHg - 255mmHg Blood Pressure Value (5.3kPa-37.3kPa) Measuring Range 40-199 pulse rates / Pulse Rate minute Pressure Value ±3mmHg (±0. 4kPa)
Page 13
Body weight About 195g±5g (excluding batteries Dimensions 120mm(length) 90mm(width) 43mm(height) Screen Size 59mm(length) 47mm(width) Upper arm cuff (measuring arm circumference 22- Cuff 36cm or 22-42cm ) Accessories Cuff, User manual High performance dry batteries can be used about 300 Battery Life times under Service Life 5 years...
EMISSIONS- for all ME EQUIPMENT and ME SYSTEMS Guidance and manufacturer’s declaration – electromagnetic emissions The Model BPM200 Electronic Blood Pressure Monitor is intended for use in the electromagnetic environment specified below. The customer or the user of the Blood Pressure Monitor should assure that it is used in such an environment.
Page 15
Table 2 Guidance and MANUFACTURER’s declaration – ELECTROMAGNETIC IMMUNITY – for all ME EQUIPMENT and ME SYSTEMS Guidance and manufacturer’s declaration – electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment.
Page 16
Table 4 Guidance and MANUFACTURER’s declaration – ELECTROMAGNETIC IMMUNITY – for ME EQUIPMENT and ME SYSTEMS that are not LIFE- SUPPORTING Guidance and manufacturer’s declaration – electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment.
Page 17
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a Field strengths from fixed transmitters, such as base stations for radio (cellular / cordless) telephones and land mobile radios, amateur radio, AM and FM radio broad- cast and TV broadcast cannot be predicted theoretically with accuracy.
Refund or replacement is at the discretion of that company. Duronic Products are offered with a 1 year guarantee under the following conditions: The product must be returned to the retailer with original proof of purchase.
Page 20
QR sur votre appareil et sul tuo dispositivo e posizionare survolez le QR code. sopra il codice QR. Vous pouvez également visiter : In alternativa, visita duronic.it duronic.fr Escanee el código QR para Scannen Sie den QR- descargar el manual de Code, um die vollständige...
Need help?
Do you have a question about the BPM200 and is the answer not in the manual?
Questions and answers