Page 3
It is the customers responsibility to ensure that all staff operating a EuroMix Silo Station are The most important thing you can do to help fully trained.
SILO SETUP PANEL ISOLATOR The isolator switch turns the electricity supply to the panel off. To completely isolate the panel the power supply MUST be Nothing will function whilst this switch is in the ‘Off’ position. To disconnected by removing the mains supply. operate the mixer, this switch must be turned clockwise to the ‘On’...
TOGGLE SWITCH This switch must always be in the down position. If the Note switch is in the up position, water will pass through the Not all control panels will contain this switch. panel and mixer and the ‘start’ and ‘stop’ buttons will not function.
MIXER MIXER ELECTRICAL INSPECTION AND TESTING All CPI EuroMix silo equipment will be inspected and tested It is the customer’s responsibility to ensure the equipment prior to the commencement of the hire. A certificate showing is safe to use whilst on site and to ensure compliance the results of the test will be issued for each piece of equipment.
The mixer operates on a timer. This timer will be adjusted during Always start the mixer with the product handle on the silo in the the set-up of your CPI EuroMix silo to suit the size of your the set-up of your CPI EuroMix silo to suit the size of your shut position (horizontal).
CPI EuroMix for a service through, call CPI EuroMix for a service narrow rubber insert section...
Page 11
Swing SWING SWING 5. Open the dry chamber by removing the securing nut with a 5. Open the dry chamber by removing the securing nut with a 5. Open the dry chamber by removing the securing nut with a 6. Clean out any material that’s left in the dry chamber and the 6.
For further advice on frost protection please refer to CPI EuroMix InfoSheet 18 in your starter pack for details. For further advice on frost protection please refer to CPI EuroMix InfoSheet 18 in your starter pack for details.
FAULT DIAGNOSIS FLOW CHART CPI EuroMix has produced a flow chart to help you diagnose Common faults include: faults and help you keep your silo working. It is often the case that • Water hoses being connected incorrectly the cause of a fault is a simple thing that can easily be rectified by the operator.
Page 15
Mixer blocked. Clean out elbow and unblock inlet ALL OK RE-ASSEMBLE Hose blocked. AND RESTART Unblock or replace hose, or call CPI for No change, No change, No change, Call CPI Call CPI new hose Call CPI Call CPI...
Page 16
Dublin Beaconsfield Coatbridge Irlam, Manchester Northfleet Bristol Springfield Farm Quarry, Gartsherrie Industrial Estate, Northbank Industrial Estate Robins Wharf, Unit 8, Broad Lane, Beaconsfield, Hornock Rd, Coatbridge Martens Road, Irlam Grove Road, Northfleet, Severnside Industrial Park, Buckinghamshire HP9 1XD ML5 2DX Manchester M44 5AX Kent DA11 9AX Central Avenue,...