Operation; Smart Space Configuration - ZeroKey ISAN10 User Manual

Table of Contents

Advertisement

ISAN10 & ISRL10 User Manual
4.4 ACTIVATING THE DEVICE
Now that the Anchor or Relay unit is secured to its
location, the device can be activated by placing the
magnetic wand in the area shown to the right. This will
wake the unit and cause it to power up, connect to the
system and commence listening for mobile units. The
LED indicator will flash red once the unit is awake and
then go to the 2 to 5 second green flash interval once it is
fully operational. Should a fault occur, the unit will either
continue to blink red or issue a series of blinks, long and
short to define an error code.

5 OPERATION

5.1 SMART SPACE CONFIGURATION

Once the unit is operating, it will continue to operate until it has exhausted its batteries. The unit should
be checked weekly to make sure that the device is still operating normally, and the batteries are not
running critically low.
5.2 BATTERY SERVICING
Both Anchor and Relay units use long lasting lithium thionyl chloride primary batteries which CANNOT
be recharged. The batteries are designed to completely deplete the lithium metal and are single use
only. Once depleted, the batteries are inert and can be disposed of in a similar manner to regular
alkaline batteries. Battery servicing should be performed by a trained technician and both batteries
MUST be replaced at the same time with fresh batteries.
WARNING DO NOT MIX OLD ANDNEW BATTERIES