TRIM CELLS

Individual cells or pairs of cells may be trimmed. This requires a test load weight.
Press 3 and ENTER.
1.
The 225D will prompt for "Cell Number(s): ".
2.
To trim a single cell, enter the cell number, and press ENTER. To trim a pair of cells,
3.
enter both cells in the form "X + Y", and press ENTER.
E.g. to trim the pair of cells 5 and 6 enter "5+6" and press ENTER.
For information only, the 225D will display the cell trim "CELL
4.
It will also display the total "SCALE WT = XXXXXX" in hi-resolution mode.
Place a test weight over the cell(s) to be adjusted.
5.
Press the SET_WT soft key.
6.
The 225D will prompt "ENTER NEW WEIGHT = ".
7.
Enter the actual correct weight of the test weight and press ENTER.
8.
The 225D will automatically trim the cell to match the entered test weight.
9.
Press the PREVIOUS and NEXT soft keys to navigate to other cells without exiting the
10.
trim menu.

SPAN ADJUST

Span adjust allows the user to tweak the span of the entire scale at once.
Press 4 and ENTER.
1.
The 225D will display the current live scale weight "SCALE WT = XXXXX.X" in high-
2.
resolution mode.
Place the test weight at any location on the scale.
3.
Press SET_WT soft key. The 225D will prompt "ENTER NEW WEIGHT = ".
4.
Enter the value of the test weight and press ENTER.
5.
The 225D will adjust the span to the target weight.
6.
24
0330-0653-0M Rev D • DC Load Cell Kit
# TRIM X.XXXXXXX".