PNEUMATIC TOOL Air Requirement The A35199 and A35599 are pneumatic tools that need a clean and dry air supply. The BAND-IT Air Regulator Module includes a filter to meet these requirements. For proper tool performance, the air requirements at the inlet to the BAND-IT Air...
Page 10
Make necessary adjustments and repairs. Be sure to remove and replace faulty clamps. Fig. 6 Warning: For A35199 tool, adjusting tension above 160 lbf may damage tool or tie (or both). Refer to website for warranty information: http://www.band-it-idex.com/warranty.html...
Page 11
For calibration procedure see Page 16& 17. Calibration with device will ensure proper tension setting. A35599 pneumatic tool used only on 0.120” wide BAND-IT Tie-Dex Micro Bands. Condition of locking lip should be visually inspected on completed clamps. If lip appears partially torn, damaged or not present at all, check tool tension and condition of blade and knife.
1. Disconnect air supply 2. Rotate filter up and unscrew clear plastic housing. 3. Unscrew filter element and clean/replace gold colored element. 4. Replacement (if necessary) must be a 5 micron filtering element, available from BAND-IT (Part# A39987) Air Filter Water Release Valve Fig.