SAMBA 55/56
Dry heat
Temperature
change (shock)
Damp heat cyclic
Cold (constant
exposure)
Table 4: Summary of reliability test conditions
This confidential document is the property of FALCOM GmbH and may not be copied or circulated without permission.
Shock duration: 1 msec
1 shock per axis
6 positions (± x, y and z)
Temperature: +70 ±2 °C
Test duration: 16 h
Humidity in the test chamber: < 50 %
Low temperature: -40 °C ±2 °C
High temperature: +85 °C ±2 °C
Changeover time: < 30 s (dual chamber
system)
Test duration: 1 h
Number of repetitions: 100
High temperature: +55 °C ±2 °C
Low temperature: +25 °C ±2 °C
Humidity: 93 % ±3 %
Number of repetitions: 6
Test duration: 12 h + 12 h
Temperature: -40 ±2°C
Test duration: 16 h
VERSION 1.03
EN 60068-2-2 Bb
ETS 300019-2-7
DIN IEC 68-2-14
Na
ETS 300019-2-7
DIN IEC 68-2-30
Db
ETS 300019-2-5
DIN IEC 68-2-1