Procedure After Replacing The Microprocessor, Etc; Firmware Update Procedure - Marantz HD-DAC1 Service Manual

Hide thumbs Also See for HD-DAC1:
Table of Contents

Advertisement

PROCEDURE AFTER REPLACING THE MICROPROCESSOR, ETC

The procedure after replacing the u-COM (Microprocessor), flash ROM, etc. is as follows.
PWB Name Ref. No.
DIGITAL
IC11
STM32F101ZE
DIGITAL
IC21
EPM240T100C5N
DIGITAL
IC32
MX25L4006EM2I
After replacing
A : The software has been written. The software is not written at the time of replacement.
B : The software has been written. The software may need to be rewritten by version updates. Check the version.
C : The software has not been written. The software needs to be written after replacement. See "Firmware
UpdateProcedure" for information on writing the software.
D : The software has been written. Be sure to rewrite with the latest software for your service region. See "Firmware Update
Procedure" for information on writing the software.

FIRMWARE UPDATE PROCEDURE

1. Procedure for upgrading IC11
1.1. Items to Be Prepared
(1) Personal Computer (Be installed "Flash_Loader_Demonstrator_v2.6.0_Setup.exe").
(2) RS-232C cable (9P (Male), Straight).
(3) SPK-581 WRITING JIG. 7P FFC(Straight)
1.2. Connecting the WRITING KIT to the unit
(1) Check that the power of this unit is turned off.
(2) Connect the RS-232C cable from PC with the WRITING KIT.
(3) Connect the WRITING KIT to the update terminal of the unit.
Upper side is contacts of
flexible card cable.
Description
7P FFC
Insert the FFC to match
the mark of 1st Pin.
WRITING KIT
After
replaced
B
SOFTWARE: SYSTEM
A
SOFTWARE: CPLD
B
SOFTWARE: DSP (USB-B)
RS-232C Cable
25
Remark
PC

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents