Initiate loopback testing from the HiGain maintenance terminal screen or use the MODE
and SEL buttons. The inband codes below can also be sent by a test set.
H2TU-C
1111110
NLOC
1111000
Network
Loopback
Inband Code
NLOC
1111000
NREM
1110000
SMJK
11000
CREM
1111110
CLOC
1111100
Loopdown
11100
Copies of this publication or the user manual can be downloaded from the ADC website at
www.adc.com. To order a hard copy, please contact your sales representative.
Message
Description
System Alarm Messages
LOSW
The HDSL2 loop has lost sync.
LLOS
No signal is detected at the DSX-1 input to the H2TU-C.
RLOS
No signal is detected at the DS1 input to the H2TU-R.
(b)
LAIS
Local AIS Signal.
(b)
RAIS
Remote AIS Signal.
(b)
LRAI
An RAI condition is detected at the remote and the signal from the line unit is error-free.
(b)
RRAI
An RAI (yellow) alarm from the Customer Premises Equipment (CPE) with a failure
from the network.
(b)
DBER
A system DS1 Bit Error Rate (BER) alarm.
(b)
PRMF
H2TU-R Performance Report Messaging BER threshold exceeded at far end.
(b)
PRMN
H2TU-R Performance Report Messaging BER threshold exceeded at near end.
HBER
A system HDSL2 Block Error Rate (BER) alarm.
MAL
The margin on the HDSL2 loop has dropped below the threshold setting.
LA
The attenuation on the HDSL2 loop has exceeded the maximum threshold value.
Line-power Alarm Messages
PWR FEED SHRT
A short between the Tip and Ring of the HDSL2 pair.
PWR FEED GND
The HDSL2 loop is grounded.
PWR FEED OPEN
A line-power open condition.
(a) System alarm messages are listed in order of priority. ALRM displays prior to any alarm message. Pressing
the SEL button initiates an Alarm CutOff (ACO) message.
(b) Does not activate the alarm relay access pin H.
(c) Line-power alarm messages display repeatedly as long as the alarm condition exists and are not included
in the priority order of the system alarm messages.
T
ESTING
CREM
110000
GNLB Loopback Commands
Description
DSX-1 signal is looped back to the network at the H2TU-C.
DSX-1 signal is looped back to the network at the H2TU-R.
DSX-1 signal is looped back to the network at the H2TU-R SmartJack
module.
Signal from customer is looped back to the customer at the H2TU-C.
Signal from customer is looped back to the customer at the H2TU-R.
Deactivates any of the above loopbacks.
Front-panel Alarm Messages
(a)
(c)
H2TU-R
TLOS
NREM
CLOC
1111100
1110000
11000
SMJK