Operation
□ Before turning on the dehumidifier, be sure that the bucket is empty and fits all
the way into the dehumidifier.
□ Each time you unplug the dehumidifier or power is interrupted, the controls will
return to the previous settings when power is restored.
□ Humidity displayed is between 30% and 90% relative humidity.
□ Humidity can be set between 30% and 80% relative humidity.
□ It's important to set the desired humidity level to an achievable setting. To ensure energy-efficient operation, only use the dehumidifier
in a closed space, with no open windows or other sources of moist air (to avoid continuous running).
□ Operating temperature is between 38°F to 90°F (3.2°C to 32.2°C). At temperatures of 38°F (3.2°C) or less, water freezes inside the
product. At temperatures over 90°F (32.2°C), the internal temperature of the product trips a protective device which deactivates the
product to avoid product damage.
□ The compressor has a 3-minute delay before restarting. If the product is stopped and immediately restarted, to protect the compressor
there is a 3-minute delay until the compressor restarts.
□ When the dehumidifier is operating, the indoor temperature will rise. The dehumidifier does not have a cooling/heating function. Heat is
generated during operation, so the room temperature may be increased by about 6°F (3°C) depending on the usage conditions (indoor
temperature, size of the room).
1
Using the Control Panel
COOL/FRAIS
POWER ON OR OFF
DRY/SEC
□ Press POWER to turn on or off the dehumidifier.
TIMER
SLEEP
/MINUT.
/VEILLE
FAN/VENT.
POWER
MODE
/MARCHE
DESIRED HUMIDITY MODE
□ Press and release MODE until you see the symbol for the desired humidity setting. Operating modes are Auto Dry,
Continuous or Manual Set.
MODE
□ Auto Dry - The dehumidifier will operate in dry mode only. The fan speed is set automatically. The desired humidity is
set to 50% automatically.
□ Continuous - The dehumidifier will operate continuously. The fan speed can be adjusted. The desired humidity can
not be adjusted.
□ Manual Set - The dehumidifier will operate at the selected fan speed to the set humidity level. If the humidity level of
the room is higher than the desired humidity setting, the compressor will turn on. If the humidity level of the room is
lower than the desired humidity setting, the compressor will turn off, as well as the fan.
NOTE: The de-icing function will turn off the compressor if a low temperature condition occurs. When the de-icer senses
the correct operating temperature the compressor will cycle back on. Some freezing is normal when dehumidifiers are used
at low temperatures.
TIMER
SLEEP
/MINUT.
/VEILLE
HIGH
/ÉLE V É
FAN
LOW
/VENT.
/FAIBLE
HIGH
/ÉLE V É
FAN
LOW
/VENT.
/FAIBLE
6
NOTE: In the event of a power failure, your
dehumidifier will operate at the previous
settings when the power is restored.
NOTE: The symbols may be
different from these models,
but the functions are similar.
NOTE: Set point is relative
humidity: lower is more dry,
higher is less dry.