Download Print this page

Delta-T Devices DL6 User Manual

Soil moisture logger
Hide thumbs Also See for DL6:

Advertisement

Quick Links

User Manual
Soil Moisture
Logger
Type DL6
DL6-UM-1.3
Delta-T Devices Ltd

Advertisement

loading
Need help?

Need help?

Do you have a question about the DL6 and is the answer not in the manual?

Questions and answers

Summary of Contents for Delta-T Devices DL6

  • Page 1 User Manual Soil Moisture Logger Type DL6 DL6-UM-1.3 Delta-T Devices Ltd...
  • Page 2 Copyright All rights reserved. Under the copyright laws, this manual may not be copied, in whole or in part, without the written consent of Delta-T Devices Ltd. Under the law, copying includes translation into another language. Copyright © 2004 Delta-T Devices Limited Trademarks Windows is a registered trademark of Microsoft Corporation.
  • Page 3: Table Of Contents

    Contents INTRODUCTION ............4 HARDWARE INSTALLATION ........5 SOFTWARE ..............11 SPECIFICATIONS ............28 MAINTENANCE, TROUBLESHOOTING, STORAGE .30 WARRANTY AND SERVICE ........33 INDEX................36 DL6 User Manual v 1.3 Contents...
  • Page 4: Introduction

    Weatherproof socket for PR2 Profile Probe cables simplifies connection. What’s New? This version of the DL6 adds support for PR2 Profile Probes and also includes Pocket PC to simplify programming, inspection and data collection in the field.
  • Page 5: Hardware Installation

    O rings Spare DL6-BAT 6 x AA alkaline cells * alkaline batteries Spare Lithium BL6-ELB 6 x AA lithium cells * batteries * see Batteries on page 30. DL6 User Manual v 1.3 Hardware Installation...
  • Page 6 There is no error. The logger is not logging. There is an error. The logger is logging. There is an error. Note: The logger also flashes when it resets. See: Reset the Logger on page 32. Hardware Installation DL6 User Manual v 1.3...
  • Page 7 Layout DL6 User Manual v 1.3 DL6 User Manual v 1.3 Hardware Installation 7 Hardware Installation 7...
  • Page 8 Connect additional soil moisture or voltage sensors to channels 5 and 6 if required. Do not connect other sensors to channels 1 to 4. Hardware Installation DL6 User Manual v 1.3...
  • Page 9 Power V+, if required Power 0V, if required Note*: To avoid ground loops, connect Signal LO to /// if and only if the sensor output is electrically isolated from both /// and OV. DL6 User Manual v 1.3 Hardware Installation 9...
  • Page 10 /// terminal (channel 7) if required. Alarm output Connect to channel 9 HI and LO Note: The alarm output switches only when the logger reads an analogue sensor e.g. soil moisture or temperature. DL6 User Manual v 1.3...
  • Page 11: Software

    One free 9-way RS232 serial port. CD ROM drive for installation. At least 10 MB of hard disk space. Logger PC RS232 cable: type DL6-RS232. DL6-SW1 software distribution disk. Installing DL6 Software Insert the distribution disk in your CD ROM drive.
  • Page 12 Check DL6 to PC Communications Connect the DL6 to your PC with the DL6-RS232 cable. Select Start, Programs, DL6 Logger, DL6 Control Panel. The first time you do this a Connection Properties dialog appears. Accept the default serial Port or change it to suit your PC, and click OK.
  • Page 13 Program the DL6 1. Select Start, Programs, DL6 Logger, DL6 Control Panel. 2. Select the Program tab on the DL6 Control Panel. 3. Select Change to edit the program. 4. Right click on channel 1 and select a sensor from the list - e.g.
  • Page 14 Note once the condition is met it stays in that state until the next logging interval, when it is re-assessed. For instance: if you are logging once per hour the relay will switch on for at least one hour. For more details select DL6 Control Panel, Help. Software DL6 User Manual v 1.3...
  • Page 15 A low rate (0.1 mm/hour) will activate fast recording for nearly all rainfall events. A medium rate (1mm/hr) will activate fast recording only for medium and heavy rain events. A high rate (5mm/hr) will activate fast recording only for very heavy rain events. DL6 User Manual v 1.3 Software 15...
  • Page 16 Note: Every tip of the rain gauge is temporarily stored with a time stamp of when it occurred. At every tip, the DL6 looks at the time stamp of the previous tip, and calculates the rate. This refreshes the "continue for X hours" condition, every time the rate is above the threshold value.
  • Page 17 2) Start +/- 0.05 m3.m-3%/hr recording every The slope exceeded this for soil moisture 10 minutes just~1½ hrs here. 400 mm 300 mm 200 mm 100 mm 0.05 0.005 0.0005 Time (hours) DL6 User Manual v 1.3 Software 17...
  • Page 18 Channel Properties Each row of the Program tab in the DL6 Control Panel lists the channel properties, these define how raw data from a sensor is to be converted into engineering units. In Program tab, if necessary, click on Change to enable program editing.
  • Page 19 Verifying Sensor Operation In the Sensors tab of the DL6 Control Panel select Read now, The readings will continually refresh a scrolling graph. DL6 User Manual v 1.3 Software 19...
  • Page 20 Datasets: retrieving, viewing, saving From the DL6 Control Panel Select the Dataset tab. Select Refresh to retrieve and view the dataset. Select View, Chart or View, Table to view it as a graph or table Select File, Save to save the dataset as a “.dt6” type data file.
  • Page 21 It will remain in the File menu, available each time you start Excel. To Import Data into Excel The wizard cannot import data directly from the DL6 (only from the DL2e). So, before running the Wizard, retrieve and save a dataset file to your PC...
  • Page 22 Dataset Import Wizard should report that it has installed itself. The Excel File menu should now contain an additional command, Import Dataset(s), which starts the Dataset Import Wizard. It will remain in the File menu, available each time you start Excel. Software DL6 User Manual v 1.3...
  • Page 23 Pocket PC Software Pocket DeltaLINK DeltaLINK for the Pocket PC is similar to the DL6 Control Panel software for your desktop PC. It provides a complete set of facilities for setting up the logger, performing sensor checks, and retrieving, viewing and saving data as dataset files.
  • Page 24 DeltaLINK Navigation Help Sensors Logger Datasets Programs Software DL6 User Manual v 1.3...
  • Page 25 Connect to Logger to communicate with a DL6 Logger b. Datasets to inspect datasets stored in the Pocket PC c. Programs to edit DL6 programs offline. Connecting to the logger To connect to the logger: Connect the logger to your Pocket PC with the cable supplied.
  • Page 26 Select Tools > Save to save the data to a dataset file. You can later open a dataset file to save the dataset as a comma-, tab- or space-separated ASCII file for importing into other programs. Software DL6 User Manual v 1.3...
  • Page 27 Select the Program window, and select Tools > Save... To save a program from a dataset file to a program file: Open a dataset file. Select the Program window, and select Tools > Save. DL6 User Manual v 1.3 Software...
  • Page 29: Specifications

    Stainless steel Mounting Plate M6 stainless steel bolt, star washer and nut x 2 M4 stainless steel screw, star washer and nut x 4 Cable tie x 2 Mounting instructions for posts & walls DL6 User Manual v 1.3 Specifications...
  • Page 30: Maintenance, Troubleshooting, Storage

    If you change the battery when logging is due you will simply miss a record. Battery Life: A DL6 reading a full set of powered sensors once an hour (e.g. 6xML2, 1x Thermistor, 1x Rain gauge) should last over a year. This would be shortened by more frequent sensor readings, temperature extremes or prolonged communications.
  • Page 31 Recalibration Period We recommend the DL6 is returned every 1 year to Delta-T for recalibration. Problems Problem Reports Always try to isolate the source of the difficulty. This may fall into one of the following areas. It will help considerably if you can mention as many relevant details as possible.
  • Page 32 Check cables and connectors If using the RS232 cable check that you are using a null modem cable, and that it is plugged into the same serial port on your PC that you have selected in the DL6 Control Panel.
  • Page 33: Warranty And Service

    Delta-T shall not be liable to the buyer by reason of any delay or failure to perform our obligations in relation to the goods and/or services, if the delay or failure was due to any cause beyond the Delta-T’s reasonable control. DL6 User Manual v 1.3 Warranty and Service...
  • Page 34 Contact details: Tech Support Team Delta-T Devices Ltd 128 Low Road, Burwell, Cambridge CB5 0EJ, U.K. email: tech.support@delta-t.co.uk Web site: www.delta-t.co.uk Tel: +44 (0) 1638 742922 Fax: +44 (0) 1638 743155 34 Warranty and Service DL6 User Manual v 1.3...
  • Page 35 CE & EMC Conformance CE conformity The DL6 conforms to EU regulations regarding electromagnetic emissions and susceptibility and is CE marked by Delta-T Devices Ltd. Warning To maintain conformance to CE standards, the equipment must be used as described in this manual. Modifications to the equipment may invalidate CE certifications.
  • Page 36: Index

    Logging Frequency, 28 charts changing the scale, 18 clock, 12 COM Port, 12 Contact details, 34 Maintenance, Trouble Shooting, Storage, Maximum Data storage, 18 Dataset tab, 20 Memory, 28 Datset Full, 12 Minimum 36 Index DL6 User Manual v 1.3...
  • Page 37 Data storage, 18 sensor parameters Mounting Kit, 5 edit, 13 sensors, 4 Sensors Sensors Tab of DL6 Control Panel, 19 Serial Cable, 5 Output Serial numbers, 31 Alarm output, 14 Service and Spares, 34 Set Clock, 12 Software Installation, 11...