Agilent 8753ES Specifications
Test-Port Output Characteristics
Frequency characteristics
Range
Option 006
Resolution
Stability
9
Option 1D5
Accuracy
Power range
2
Option 075/014
Power sweep range
Resolution
Level accuracy
1,2,5
Level linearity
1,2,5
Impedance
9
30 kHz to 3 GHz
3 GHz to 6 GHz
Option 075
30 kHz to 3 GHz
Spectral purity
2nd harmonic
3
Option 002
3rd harmonic
4
Option 002
Nonharmonic spurious
9
Mixer related
10
7
30 kHz to 3 GHz
30 kHz to 6 GHz
1 Hz
±7.5 ppm (0° to 55° C)
±3 ppm/year
±0.05 ppm (0° to 55° C),
±0.5 ppm/year
±10 ppm at 25° ±5° C
-85 to +10 dBm
-85 to +8 dBm
25 dB (typically 31 dB)
0.01 dB
±1.0 dB
-15 dBm to +5 dBm ±0.2 dB
5 dBm to 10 dBm
6
±0.5 dB
50 Ω (nominal)
>16 dB RL (<1.38 SWR)
>14 dB RL (<1.50 SWR)
75 Ω (nominal)
>16 dB RL (<1.38 SWR)
<-40 dBc at 0 dBm
9
<-50 dBc at -10 dBm
9
<-25 dBc at 10 dBm
6
<-40 dBc at 0 dBm
9
<-50 dBc at -10 dBm
9
<-25 dBc at 10 dBm
6
<-30 dBc at 10 dBm
6
<-55 dBc at -10 dBm
Test-Port Input Characteristics
Frequency range
Option 006
Average noise level
2,8
<3 GHz
<3 GHz
<3 GHz
3 to 6 GHz
3 to 6 GHz
3 to 6 GHz
Maximum input level
Damage level
Impedance
Option 075
Frequency response
2,5
300 kHz to 3 GHz
3 GHz to 6 GHz
Internally generated harmonics (Option 002)
2nd harmonic
3
3rd harmonic
4
Harmonic measurement accuracy
300 kHz to 3 GHz
3 GHz to 6 GHz
Harmonic measurement dynamic range
-40 dBc (output = -10 dBm, input = <-15 dBm)
Frequency offset mode
11
Frequency range
Option 006
R-channel input requirements
Power level
300 kHz to 3 GHz
3 GHz to 6 GHz
LO spectral purity (typical)
Maximum spurious input <-25 dBc
Residual FM
LO frequency accuracy
9
1. Relative to 0 dBm output power.
2. Typical below 300 kHz.
3. 16 MHz to 3 GHz.
4. 16 MHz to 2 GHz.
5. Typical from 2 to 3 GHz for instruments with Option 075.
6. +8 dBm maximum with Option 075, or Option 014.
7. Test performed on port 1 only.
8. Instruments with Option 075 are degraded 2 dB.
9. Typical performance.
10. 25° ±5° C.
11. The Agilent 8753ES source characteristics and measurement accuracy in this
mode are dependent on the stability of the external LO source. The RF source
tracks the LO to maintain a stable IF signal at the R-channel receiver input.
Degradation in accuracy is negligible when using an Agilent 8642A/B, 8656B,
or E4432B RF signal generator as the LO source.
30 kHz to 3 GHz
30 kHz to 6 GHz
<-82 dBm (3 kHz BW)
<-102 dBm (10 Hz BW)
<-110 dBm (10 Hz BW) typical
<-77 dBm (3 kHz BW)
<-97 dBm (10 Hz BW)
<-105 dBm (10 Hz BW) typical
10 dBm
26 dBm or 35 VDC
50 Ω (nominal)
75 Ω (nominal)
±1.0 dB
±2.0 dB
<-15 dBc at +8 dBm
<-30 dBc at 0 dBm
9
<-45 dBc at -15 dBm
9
<-30 dBc at +8 dBm
<-50 dBc at 0 dBm
9
<-50 dBc at -15 dBm
9
10
±1.5 dB
±3 dB (Option 006)
9
300 kHz to 3 GHz
300 kHz to 6 GHz
0 to -35 dBm
0 to -30 dBm
<20 kHz
±1 MHz at nominal frequency

Hide quick links: