9.
Prior to making the vent connections, apply high temperature
sealant (1000°F min.) to the vent connections before
securing with the band clamps provided. NOTICE: the
flue pipe end without the adapter is to be installed to the
Termination Cap.
10. Apply sealant to the outside of the flue pipe adapter and
connect to the flex flue pipe. Then insert the adapter into
the 45° elbow's inner flue pipe. Secure flue adapter with a
minimum of two screws provided. See Figure 57.
11. Attach the Outer Vent pipe to the 45° elbow with a large
band clamp provided. Sealant may also be used on the outer
vent connections.
12. Check all vent connections for tightness. Make sure
horizontal venting has the proper rise and combustible
clearances required. Refer to venting charts in fireplace
instruction manual.
8" DIAMETER FLEX
VENT PIPE
5" DIAMETER FLEX
FLUE PIPE
5" DIAMETER
FLUE ADAPTOR
COLLAR
Page 34
DVVK-5F FLEX VENT INSTRUCTIONS
BAND CLAMP
APPLY HIGH
TEMPERATURE
SEALANT
Figure 57
Figure 58
36092-5-0318