Troubleshooting – Specifications
Problem
Engine is running, but no
AC output is available.
Engine runs good at
no-load but "bogs down"
when loads are connected.
Engine will not start; starts
and runs rough or shuts
down when running.
Engine lacks power.
Engine"hunts"or falters.
Engine shuts down when
running.
For all other issues, contact authorized dealer or Firman customer service.
English
Cause
1. Circuit breaker is open.
2. Fault in generator.
3. Poor connection or defective cord set.
4. Connected device is bad.
1. Short circuit in a connected load.
2. Engine speed is too slow.
3. Shorted generator circuit.
4. Clogged or dirty fuel filter.
1. Fuel switch set to OFF (O)
position.
2. The indicator light is OFF or
flashing red.
3. Low oil level.
4. Dirty air cleaner.
5. Out of gasoline.
6. Stale gasoline.
7. Spark plug wires not connected
to spark plugs.
8. Bad spark plugs.
9. Water in gasoline.
10. Flooded.
11. Excessively rich fuel mixture.
12. Clogged or dirty fuel filter.
13. Starting battery may have
insufficient charge.
14. Out of battery power.
1. Load is too high.
2. Dirty air filter.
3. Clogged or dirty fuel filter.
4. Clogged spark arrester.
1. Carburetor is running too rich or too lean. 1. Contact authorized service facility.
2. Clogged or dirty fuel filter.
1. Out of gasoline.
2. Dirty air cleaner.
3. Low oil level.
Correction
1. Reset circuit breaker.
2. Contact authorized service facility.
3. Check and repair.
4. Connect another device that is in
good condition.
1. Disconnect shorted electrical load.
2. Contact authorized service facility.
3. Contact authorized service facility.
4. Clean or replace fuel filter.
1. Set fuel switch to "ON" position.
2. Must have solid red indicator light
to be able to start the engine.
3. Fill crankcase to proper level or
place generator on level surface.
4. Clean or replace air cleaner.
5. Fill fuel tank with gasoline.
6. Drain fuel tank and carburetor; fill
with fresh gasoline.
7. Connect wires to spark plugs.
8. Replace spark plugs.
9. Drain gas tank and carburetor; fill
with fresh gasoline.
10. Wait 5 minutes and re-crank engine.
11. Contact authorized service facility.
12. Clean or replace fuel filter.
13. Check battery output and charge
battery as necessary.
14. Start Engine to charge or
replace battery.
1. Don't Overload Generator
2. Replace air filter.
3. Clean or replace fuel filter.
4. Clean or replace spark arrester.
2. Clean or replace fuel filter.
1. Fill fuel tank with gasoline.
2. Clean or replace air cleaner.
3. Fill crankcase to proper level or place.
generator on level surface.
27