Ortur OLM2 PRO S2 Setting Instructions

Ortur OLM2 PRO S2 Setting Instructions

Vibration detection and flame detection sensitivity

Advertisement

OLM2 PRO S2 vibration detection and flame detection
sensitivity setting instructions
Note: This document applies only to OLM2 PRO S2 models
1. Vibration detection & flame detection sensitivity adjustment and closure

1.1 Operate on laserGrbl software

1.1.1 Connecting the Device using laserGrbl
1.1.2 On the software menu bar, click Grbl and then click Grbl Configuration to enter the Grbl
parameter Configuration page
1.1.3 Grbl parameters related to flame and vibration detection:
$260: Flame detection count threshold, higher to reduce sensitivity, lower to increase sensitivity,
used with $261;The default value is 15.
$261: Fire test count trigger alarm threshold, higher to reduce sensitivity, lower to increase
sensitivity, use with $260;When 0, the flame detection function is off;The default value is 250.
$262: trigger threshold of vibration detection count, which can be adjusted to reduce the
sensitivity and lowered to improve the sensitivity;When the value is greater than 1000, the
function becomes invalid.
Click the value in the "Value" column. After changing the value, click the "Write" button to make
the setting take effect

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OLM2 PRO S2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ortur OLM2 PRO S2

  • Page 1 OLM2 PRO S2 vibration detection and flame detection sensitivity setting instructions Note: This document applies only to OLM2 PRO S2 models 1. Vibration detection & flame detection sensitivity adjustment and closure 1.1 Operate on laserGrbl software 1.1.1 Connecting the Device using laserGrbl 1.1.2 On the software menu bar, click Grbl and then click Grbl Configuration to enter the Grbl...
  • Page 2 1.2 Using the Lightburn software 1.2.1 Grbl parameters related to flame and vibration detection: $260: Flame detection count threshold, higher to reduce sensitivity, lower to increase sensitivity, used with $261;The default value is 15. $261: Fire test count trigger alarm threshold, higher to reduce sensitivity, lower to increase sensitivity, use with $260;When 0, the flame detection function is off;The default value is 250.

Table of Contents