Download Print this page

Jantar REX K-1-7 Manual page 3

Advertisement

Function 9) Switch to Wiegand 26-bit or table reader
Switch the controller to a Wiegand 26-bit reader or a table reader.
Table reader sends a card number through RS485. The controller
can be changed back to standalone controller with master code.
The controller signals, when in Wiegand 26-bit mode or table
reader mode with flashing red and green LED.
Switch:
Approach the master card and remove it after 9 double beeps. The
controller will start to beep every second. Each beep presents a
different function, which is selected with a user card.
2. beep – If a user card is approached after 2 beeps, the controller
will switch to Wiegand 26-bit reader.
3. beep – If a user card is approached after 3 beeps, the controller
will switch to table reader.
Switch from Wiegand 26-bit or table reader to controller:
Enter the master code and press  . Press 9 and  . Press 1 and  .
Function 13) Delete all
Reset/ delete all data to default.
SETUP:
Approach the master card and remove it after 13 double beeps.
Within a period of three seconds approach a user card. This will
delete all data and reset the controller to default settings. The
controller confirms this, after three seconds, with one long and
triple beep.
Programming Rex with the master code
The default master code is 1234. The maximum code length
is 6 digits. The master code must be CHANGED for security
reasons, because the default one is written in controller's
manual and with it, anybody can set himself his own code,
to open YOUR door.
PROGRAMMING FUNCTIONS WITH MASTER CODE
Function
Description
0
Change master code
1
Register or delete user codes
2
Pulse time/ Duration of active output or toggle mode
3
Door status switch input/ time till pre-alarm
4
Pre-alarm and alarm/ duration of pre-alarm
5
Negate output
9
Switch to Wiegand 26-bit
13
Delete all
Function 0) Master code
Change the master code.
Setup:
Enter the default master code and press  . Press 0 and  . Enter
the new master code and press  . Again enter the new master
code and press  . Store the master code in a secure place.
Function 1) User codes
Register or delete user codes.
Setup:
Enter the master code and press  . Press 1 and  . Enter the new
user code and press  . Again enter the new user code and press  .
User code is now registered and with it, you can open output on
the controller. If the code has already been registered, it is now
deleted. Next code or card you register, will take the first empty
position in the system.
Function 2) Pulse time/ Duration of active output or toggle
mode
Set the duration of active output/ the time in which you can open
door or set output to toggle mode. Toggle mode means, if the user
card is registered, output will remain opened (if it was closed) or
closed (if it was open) till next registration.
Black line
REX K-1-7 – Standalone or access controller
Set the duration of active output:
Enter the master code and press  . Press 2 and  . Enter the
duration of active output in seconds (max. 60seconds) and press  .
Set toggle mode:
Enter the master code and press  . Press 2 and  . Press 0 and  .
Function 3) Door status switch input
Set the time till the pre-alarm / time for which door can stay open,
without triggering the pre-alarm and consequently the alarm. This
function is used when the door status switch on el. strike is
connected to Input0/I0/wire 5 on the controller:
Setup:
Enter the master code and press  . Press 3 and  . Enter the
duration of time till pre-alarm in seconds (max. 60 seconds) and
press  .
Function 4) Pre-alarm and alarm
Set the pre-alarm time. This is the time in which the controller,
with short beeps, alerts you that door was left open. If you don't
close the door in the pre-alarm time, the alarm will be triggered
and signaled with long beeps by the controller.
Setup:
Enter the master code and press  . Press 4 and  . Enter the
duration of pre-alarm time in seconds (max. 60 seconds) and press
 .
Function 5) Negate / switch output state
This function is used when you connect an electric strike or electric
magnet which needs power supply to remain in locked state.
Turn on the negated output:
Enter the master code and press  . Press 5 and  . For
confirmation press 1 and  . The output state will be switched from
the current one.
Function 9) Switch to Wiegand 26-bit or table reader
Switch the controller to a Wiegand 26-bit reader or a table reader.
Table reader sends a card number through RS485. The controller
can be changed back to standalone controller with master code.
The controller signals, when in Wiegand 26-bit mode or table
reader mode with flashing red and green LED.
Switch:
Enter the master code and press  . Press 9 and  .
Press:
2 and  – The controller will switch to Wiegand 26-bit reader.
3 and  – The controller will switch to table reader.
Switch from Wiegand 26-bit or table reader to controller:
Enter the master code and press  . Press 9 and  . Press 1 and  .
Function 13) Delete all
Reset/ delete all data to default:
Enter the master code and press  . Press 13 and  . For
confirmation press 1 and  . This will delete all data and reset the
controller to default settings. The controller confirms this, after
three seconds, with one long and triple beep.
Default settings
A three-second pulse, five-second open time, four-second pre-
alarm time, door switch and push button have NO contact; output
is set for fail secure el. strike. The controller is in standalone mode.
REX K- ACCESS CONTROLLER
As an access controller, it is intended for controlling entries, exits
and passes of users in the system and controlling sliding doors,
ramp, el. strike, turning alarm on/off... It needs to be set with V7,
STOP, BLOCKER or CODEKS software.
11/2012
www.codeks.eu