Installation of Rex K
Remove black plastic screw covers on the top and
the bottom of the controller. Install the controller
to the wall with two supplied screws. Use diagonal
holes - it enables a small correction of the position
of the controller (up, down, left, right). When the
controller is installed, put the screw covers back
on
.
REX K - STANDALONE CONTROLLER
The entire set-up procedure is carried out with the master card or
code.
The master card and code cannot be replaced or duplicated.
After registration the master card and code should always
be kept in a secure place. You cannot change any setting
without them and neither can we. Keep that in mind when
storing the master card and code.
Programming Rex with the master card
First connection to power supply and registration of the
master card:
Turn the power supply on (2 beeps indicate power on). Approach a
card, you will use as a master card (3 beeps indicate a successful
registration). The first card registered becomes master card. All
the other cards will be registered as users (user cards).
Usage of master card:
If you hold the master card in front of the controller, every two
seconds a double beep is heard. The number of double beeps
indicates the programming function.
PROGRAMMING FUNCTIONS WITH MASTER CARD
Function
Description
1
Register or delete user cards
2
Pulse time/ Duration of active output or toggle mode
3
Door status switch input/ time till pre-alarm
4
Duration of pre-alarm
5
Negate output
6
Delete a lost card
7
Delete a lost card
9
Switch to Wiegand 26-bit or table reader
13
Delete all
Function 1) User cards
Register or delete user cards.
SETUP:
Approach the master card and remove it after 1 double beep.
Within a period of three seconds approach a user card. The user
card is now registered and with it, you can open output on the
controller. If the card has already been registered, it is now deleted
and its position is now empty. Next registered card will take the
first available position on the list or position of the deleted card. To
delete a lost user card, you must maintain a list of registered cards
and codes, arranged in order of registrations (positions).
Function 2) Pulse time/ Duration of active output or toggle
mode
Set the duration of active output/ the time in which you can open
door or set output to toggle mode. Toggle mode means, if the user
card is registered, output will remain opened (if it was closed) or
closed (if it was open) till next registration.
Black line
REX K-1-7 – Standalone or access controller
Set the duration of active output:
Approach the master card and remove it after 2 double beeps. The
controller will start to beep every second. Each beep indicates 1
second of active output. Duration of active output can be max. 60
seconds. When you hear the required number of beeps, approach a
user card for confirmation.
Set toggle mode:
Approach the master card and remove it after 2 double beeps.
Approach a user card before the first beep. Toggle mode is
selected.
Function 3) Door status switch input
Set the time till pre-alarm / time in which the door can stay open,
without triggering the pre-alarm and consequently the alarm. This
function is used when the door status switch on el. strike is
connected to Input0/I0/wire 5 on the controller.
SETUP:
Approach the master card and remove it after 3 double beeps. The
controller will start to beep every second. Each beep indicates 1
second till pre-alarm. Duration of the time till pre-alarm can be
max. 60 seconds. When you hear the required number of beeps,
approach a user card for confirmation.
Function 4) Pre-alarm and alarm
Set the pre-alarm time. This is the time in which the controller,
with short beeps, alerts you that the door was left open. If you
don't close the door in the pre-alarm time, the alarm will be
triggered and signaled with long beeps by the controller.
SETUP:
Approach the master card and remove it after 4 double beeps. The
controller will start to beep every second. Each beep indicates 1
second of the pre-alarm time. Duration of the pre-alarm time can
be max. 60 seconds. When you hear the required number of beeps,
approach a user card for confirmation.
Function 5) Negate / switch output state
This function is used, when you connect an electric strike or electric
magnet which needs power supply to remain in locked state.
SETUP:
Approach the master card and remove it after 5 double beeps.
Within a period of three seconds approach a user card. The output
state will be switched from the current one.
Function 6) Delete a lost card
Delete the next card on the list. Use this function if you lost a card
and you wish to delete it from the controller. In order to use this
function you must maintain a list of registered cards and codes,
arranged by order of registrations so that you can find the card or
code, which was registered before the lost one.
SETUP:
Approach the master card and remove it after 6 double beeps.
Within a period of three seconds approach the user card, which was
registered before the lost one. This will delete the lost user card.
Next registered card will take the position of a deleted card.
Function 7) Delete a lost card
Delete the previous card on the list. Use this function if you lost a
card and you wish to delete it from the controller. In order to use
this function you must maintain a list of registered cards and
codes, arranged by order of registrations so that you can find the
card or code, which was registered after the lost one.
SETUP:
Approach the master card and remove it after 7 double beeps.
Within a period of three seconds approach the user card, which was
registered after the lost one. This will delete the lost user card.
Next registered card will take the position of a deleted card.