Page 1
AP PROOFER Installation and Operating Manual For service information call 800-544-3057 Please have the following information available before calling. Information can be found on the identification/certification tag: •Model Number •Serial Number •Date of Purchase •Part Description and number as shown in parts list...
Congratulations! You have just purchased one of the finest pieces of equipment on the market today. Before installing or operating your new Piper equipment, you should read through this manual. This manual should be retained for further reference as it contains installation and operating instructions, service tips, part lists and warranty information.
1. Tilt unit backward at a 45˚ angle. 2. Push down on front of skid breaking off narrow board on back. 3. Remove skid by pulling forward. YOUR SHIPMENT SHOULD CONSIST OF: AP Proofer 2 - Side racks 1 - Water Pan ASSEMBLY INSTRUCTIONS Place the stainless steel water pan into the opening in the bottom of the unit, on top of the heating element.
INSTALLATION ELECTRICAL CONNECTION WARNING!!!! DO NOT USE EXTENSION CORDS (VOIDS WARRANTY) Ground: The electrical outlet must be provided with an efficient ground, and the voltage and the frequency of the electrical line matches those indicated on the data plate. If unsure about the efficiency of the ground, have your electrical circuit checked by a qualified technician.
ELECTRICAL RATING VOLTS PHASE WIRE* AMPS WATTS HERTZ 1550 Installation should be made by a licensed electrician. Check local codes for vent hood requirments. * Number of wires does not include ground. PROOFER OPERATING INSTRUCTIONS 1. Turn power switch ON. 2.
CAUTION: Prior to cleaning or maintenance, turn all switches “OFF” and disconnect the power. Unit should be cleaned daily. Stainless Steel and Aluminum: • Piper only approves soap and water for cleaning stainless steel. • NOTICE: Do NOT use chlorinated cleaners. Hardened Foods or Scale Deposits: •...
(The humidity control operates like a regulator. The indicator light will cycle “on” longer as the dial setting is adjusted higher). Check if proofer blower is operating. Check to see if door fits properly. Call Piper Products directly at 800-544-3057 if you need further assistance.
WIRING DIAGRAM blower motor 500 WATTS 1045 WATTS NEMA 5-15...
Page 12
Piper Products Service Department shall be final. Any defective parts to be repaired or replaced must be returned to Piper Products, Inc., 300 South 84th Avenue, Wausau, WI 54401, transportation charges prepaid, and they must be properly packed and tagged.
Page 13
Piper Products, Inc 300 South 84th Avenue Wausau, WI 54401 Phone: 715-842-2724 . FAX: 715-842-3125...
Need help?
Do you have a question about the AP PROOFER and is the answer not in the manual?
Questions and answers