Description (normal operating messages in bold)
A=xx
The loop attenuation of the longest (maximum loss) span, measured in dB.
ACQ
The multiplexers of the H2TU-C-231 and H2TU-R are trying to establish synchronization.
AnL
The multiplexers of the two devices on Span n are trying to establish synchronization with
each other, where n is the number of the span.
ARM
Armed to respond to Intelligent Repeater Loop (ILR) codes.
BAD RT?
The H2TU-C is not receiving a response from the H2TU-R.
FERR
A framing bit error occurred at H2TU-C DSX-1 input.
FLDL
Flash download of firmware updates. (Contact Customer Service for update procedcures.)
HES
H2TU-C HDSL2 loop cyclical redundancy check (CRC) error.
LBPV
A local bipolar violation has been received at the DSX-1 input to the H2TU-C.
M=xx
Indicates the power of the received HDSL2 signal relative to noise (S/N with respect to 21.5 dB).
Any value of 6 dB or greater is adequate for reliable system operation.
MNGD
The H2TU-C is under control of the HMU-319 network management unit.
PWR FEED OFF HDSL2 span power is turned off.
PWR FEED ON
Indicates that the HDSL2 loop is not grounded or shorted.
SIG
The transceivers of the H2TU-C and H2TU-R (or the H2TU-C and first regenerator) are
trying to establish contact with each other on Span 1 of the HDSL2 loop.
SnL
The transceivers of the two devices on Span n are trying to establish contact with each
other, where n is the number of the span.
Message
Description (default values in bold)
VER x.xx
Software version number x.xx.
LIST xx
List number of the H2TU-C-231.
FRM xxxx
Frame (SF, ESF, UNFR).
CODE xxxx Line code setting (AMI or B8ZS).
LATT xx
Loop Attenuation threshold setting (38).
MARG xx
Margin threshold setting(4).
EQL
Sets the DSX-1 Equalizer to: EXT (replaces internal equalizer with external equalizer), 0 (0 to 132
ft.), 133 (133 to 265 ft.), 266 (266 to 398 ft.), 399 (399 to 532 ft.), 533 (533 to 655 ft.).
RLBO
Sets the H2TU-R line buildout to 0.0 dB, -7.5 dB, or -15 dB.
LPBK
Enables (ENA) or disables (DIS) SmartJack loopback commands.
SPLB xxxx
Configures system for generic (GNLB) or special inband loopback commands (A1LB, A2LB, A3LB, A4LB,
A5LB).
PWRF
OFF = disables HDSL2 powering; ON = HDSL2 line voltage is -185 Vdc maximum.
HBER
1E-6 or 1E-7 = alarm activates when the HDSL2 BER alarm threshold exceeds 10
= prevents generation of a system alarm due to BER.
DBER
Enables (ENA) or disables (DIS) fixed 24-hour DSX-1 BER alarm threshold.
LBTO
Loopback timeout = NONE, 20, 60, 120 minutes.
ALM
Enables (ENA) or disables (DIS) alarm indications on pins 20 and 21.
DS1
DSX-1 line code = Bipolar with 8-Zero Substitution (B8ZS), Alternate Mark Inversion (AMI).
CONV
H2TU-R frame format conversion = OFF (framing determined by the DS1 FRMG option), ACON
(autodetection of framing and potential frame conversion at the H2TU-R), or FCON
(autodetection of framing and forced frame format conversion at the H2TU-R).
FRMG
DS1 frame formatting = AUTO (auto framing mode) or UNFR (unframed mode),
RDA
Enables (ENA) or disables (DIS) alarm indications due to remote DS1 LOS at H2TU-R input.
ALMP
Enables system to output an alarm pattern: Alarm Indication Signal (AIS) or Loss of Signal (LOS).
BPVT
Enables (ENA) or disables (DIS) Bipolar Violation Transparency (BPVT).
NLBP
Enables the H2TU-R to transmit either AIS or LOS towards CI for any network loopback.
TLOS
Enables (ENA) or disables (DIS) a logic loopback at the H2TU-R when an LOS occurs at its DS1 input.
PRM
OFF = no enhanced Performance Report Messaging; SPRM = Supplemental PRM;
NPRM = Network PRM; AUTO.
NAIS
If ALMP is set to AIS, this option specifies which pattern is sent to the network when a remote
LOS or AIS occurs. CI = AIS-CI sent to the network; AIS = AIS sent to the network.
ROVR
Enables (ENA) or disables (DIS) conversion of an ESF DS1 payload from the network with an
embedded RAI pattern to an SF-RAI pattern towards the CI at the H2TU-R. CONV option must
be set to FCON or ACON.
RACI
Enables (ENA) or disables (DIS) conversion of a DS1 RAI alarm (yellow LED) signal received by
the H2TU-R to be converted to an RAI-CI signal towards the network.
PBON
Configures the power output levels of the H2TU-C network unit toward the customer to comply
with Default (DEF) or Enhanced (ENH) templates.
PBOC
Configures the power output levels of the H2TU-C customer unit toward the network to comply
with Default (DEF) or Enhanced (ENH) templates.
(a) Front-panel codes scroll in the order listed. The configured selections follow each code.
Front-Panel Diagnostic Messages
Front-Panel Read-Only Settings Using MODE
(a)
-6
-7
or 10
. NONE