COMPUTHERM Q8RF (TX)
Wireless (radio frequency) programmable
digital room thermostat (without receiver)
Operating Instructions
You can watch the most important aspects of the usage of this thermostat
on our video presentation at www.computherm.info

Advertisement

loading

Summary of Contents for Quantrax COMPUTHERM Q8RF

  • Page 1 COMPUTHERM Q8RF (TX) Wireless (radio frequency) programmable digital room thermostat (without receiver) Operating Instructions You can watch the most important aspects of the usage of this thermostat on our video presentation at www.computherm.info...
  • Page 2 GENERAL DESCRIPTION OF THE THERMOSTAT The COMPUTHERM Q8RF (TX) type switched-mode room thermostat is suitable to regulate the overwhelming majority of boilers and air conditioners. It can be used together with the COMPUTHERM Q5RF and Q8RF multi-zone thermostats to complement the two thermostats in the basic package, to increase the number of zones regulated and to control the COMPUTHERM Q1RX wireless (radio-frequency) thermostat-controlled socket.
  • Page 3 Boiler Thermostat Reciever 230 V AC, 50 Hz Zone valves 230 V AC, 50 Hz To increase the lifetime of the batteries, the thermostat will not transmit signals continuously. Instead it will repeatedly transmit the actual signal every 8 minutes. Therefore, the regulation of the heating or cooling will continue even after a blackout.
  • Page 4 The effective range of the transmitter incorporated in the thermostat is approximately 50 m in open terrain. This distance may become considerably shorter within a building, especially when a metal structure, reinforced concrete or adobe wall stands in the way of radio waves.
  • Page 5 1. LOCATION OF THE DEVICE The thermostats of the COMPUTHERM Q8RF (TX) multi-zone programmable wireless type device can be freely moved in your residence. It is reasonable to locate them in rooms used regularly or for many hours per day so that they are in the direction of natural ventilation in the room but protected from drought or extreme heat (e.g.
  • Page 6 The battery compartment is in the inner side of the front panel of the housing. Insert 2 AA alkaline batteries (LR6 type) in accordance with the diagram in the battery compartment. Warning! Good quality alkaline batteries may only be used for this appliance. Carbon-zinc batteries known as durable or long life batteries and chargeable accumulators are not suitable for the operation of this appliance.
  • Page 7 Using the large buttons on the front panel of the device, set the the cur- rent day (Monday MON; Tuesday TUE; Wednesday WED, etc.). Press the “DAY” button again. At this time the contraction indicating the day stops flashing and becomes visible continuously while the abbreviation indicating the hour will flash on the display.
  • Page 8 To switch between the two modes, 1st press the “SET” button to go to the main screen. Then press the “SET” button again and hold it down and press the “COPY” button, too. After this, the notice “ ” or “ ”...
  • Page 9 To change the switching sensitivity, 1st press the “SET” button to go to the main screen. Then press the “DAY” and “COPY” buttons one after the other. Following this, select the desired switching sensitivity using the large buttons. The notices “...
  • Page 10 The pump protection function can accomplish its task only if the boiler is in working order in the summer, too. It is reasonable to set a low temperature level, e.g. +10°C, on the thermostat for this period, to prevent the boiler from unnecessary start-ups when the weather turns cold temporarily.
  • Page 11: Programming The Thermostat

    the connection points NO and COM of the receiver output relay are closed at temperatures below 21.8 °C (heating is turned on) and 230 V AC is displayed on the output for that zone. The NO and COM conection points are opened at temperatures above 22.2 °C (heating is turned off) and the 230 V AC voltage at its output for that zone is turned off.
  • Page 12 • The start time of switch PROG is , which cannot be changed, only its temperature can be adjusted. So under the factory default settings, the thermostat performs only one switch (PROG ) every day, which is in effect from until the next day.
  • Page 13 are flashing on the display. The modification of these values can always be done using the large buttons. The confirmation of a value is always done by pressing the “PROG” button, after which the next value can be adjusted. The program can be saved by pressing the “SET”...
  • Page 14 of the day, when the family is at work or school, only a lower temperature is needed. As heating up and cooling down usually takes a long time, it is reasonable to set the start time of the switches 0.5-1 hour before the desired time of the modified temperature. The programmability of the thermostat provides a perfect solution for this.
  • Page 15 choose all days of the week simultaneously (by selecting MON TUE WED THU FRI SAT SUN together), this way there is no need to perform separate programming of the days. After selecting the desired day(s), press the PROG” button. “ d.
  • Page 16 . This way the programming of the selected day(s) is finished, the thermostat offers another day to be programmed and the programming can be continued from step “c ”. If all the switches (PROG ‒ PROG ) are activated for the selected day(s), then after setting the temperature value of PROG , the programming of the selected day(s) is finished, the thermostat offers another day to be programmed and the programming can be continued from step “c ”.
  • Page 17 • Press the “COPY” button to copy the program of the selected day. After this, the flashing of the abbreviation indicating the day that has been copied stops and it will be visible continuously hereafter. • Select the day to which you wish to copy the program of the day copied beforehand using the large buttons.
  • Page 18 • The number of activated switches can be increased at will as described in Section 4.3. • A previously activated switch can be deactivated by setting its start time to using the large buttons (or by pressing the “DAY” button once), and then pressing the “PROG”...
  • Page 19 • Repeatedly press the “PROG” button to check the values of switch PROG , PROG , etc. Use the large buttons to change the day(s). If all the days were programmed together (MON TUE WED THU FRI SAT SUN), then their common program can only be viewed together.
  • Page 20 The economy and comfort temperature values assigned to buttons be modified as follows: • To set the economy temperature, press the “SET” button and keep it depressed and press the button, too. Following this, with the help of the buttons, set the economy temperature selected by you.
  • Page 21 control (for example , that is, 4 hours and 2 minutes). After this time has elapsed, the icon disappears and the device resumes the program that has been set. If you wish to return to the set program before the time of the next switch is reached, please press the “SET”...
  • Page 22 5.3 Temperature modification for 1-99 days (holiday program) Set the required temperature using the large buttons on the front panel of the device. After the temperature modification the program number disappears, at this time the icon appears on the display, indicating that the thermostat is operated with manual control.
  • Page 23: Turning On The Backlight

    5.4 Temperature modification until the next manual interference Set the required temperature using the large buttons on the front panel of the device. At this time, the icon appears on the display, indicating that the thermostat is operated with manual control. Then, press the “HOLD” button briefly, after which the icon appears and the icon disappears.
  • Page 24: Locking The Control Buttons

    then this automatic backlight function turns off and the “   ” notice is shown on the display for 3 seconds. 7. LOCKING THE CONTROL BUTTONS The thermostat enables you to lock its control buttons. With this function, you can prevent unauthorised modification of the program or the set temperature.
  • Page 25: Fault Settings

    Warning! Good quality alkaline batteries may only be used for this appliance. Carbon- zinc batteries known as durable or long life batteries and chargeable accumulators are not suitable for the operation of this appliance. Icon appearing on the display to indicate low battery voltage warns reliably that the batteries should be replaced only when good quality alkaline batteries are used.
  • Page 26 SOCKET TOGETHER 10.1 COMPUTHERM Q8RF (TX) - COMPUTHERM Q5RF/Q8RF If you would like to use the COMPUTHERM Q8RF (TX) thermostat to complement the COMPUTHERM Q5RF multi-zone thermostat, then follow the tuning steps described in Section 7.2 of the manual of the COMPUTHERM Q5RF thermostat or to complement the COMPUTHERM Q8RF multi-zone thermostat, then follow the tuning steps described in Section 10.2 of the manual of the COMPUTHERM Q8RF thermostat.
  • Page 27 11. TRANSMISSION DISTANCE INSPECTION With the help of the “TEST” button of the thermostats you can check whether the selected thermostat and the receiver unit are within the transmission distance of the radio- frequency connection. To perform the test, press the “TEST” button for approximately 3 seconds.
  • Page 28: Frequently Asked Questions

    FREQUENTLY ASKED QUESTIONS When you think that your appliance is operating incorrectly or encounter any problem while the appliance is being used then we recommend that you read Frequently Asked Questions (FAQ) available on our website, where we collected the problems and questions that most frequently occur while our appliances are being used, along with the solutions thereto: www.computherm.info/en/faq...
  • Page 29 A BRIEF DESCRIPTION OF PROGRAMMING • Setting the date and time: press the “DAY” button, then adjust values using the “DAY”, buttons. • Programming: press and hold down the “SET” button, while pressing the “PROG” button too, then adjust values with the “PROG”, buttons;...
  • Page 30 PRODUCT INFORMATION DATA SHEET: • Trademark: COMPUTHERM • Model identifier: Q8RF (TX) • Temperature control class: I. class • Contribution to the efficiency of seasonal space heating: 1% Remark: In addition to using modern temperature regulators, the following up-to-date regulation methods also contribute significantly to the improvement of the comfort provided by the heating network, the energy efficiency of the heating network and the coefficient of performance: •...
  • Page 31 Technical data of the thermostat: — temperature measurement range: 3 to 45 °C (in 0.1 °C increments) — adjustable temperature range: 5 to 40 °C (in 0.5 °C increments) — temperature measurement accuracy: ±0.5 °C — temperature calibration range: ±3 °C (in 0.1 °C increments) —...
  • Page 32 E-mail: iroda@quantrax.hu Web: www.quantrax.hu • www.computherm.info designed in the EU, made in China Origin: Please watch our video presentation of the most important aspects of the usage of this thermostat at our websites! Copyright © 2020 Quantrax Ltd. All rights reserved.