Milestone pro MP-MU44-3.2 User Manual

4x4 usb 3.2 matrix

Advertisement

Quick Links

User Manual
MP-MU44-3.2
4x4 USB 3.2 Matrix
All Rights Reserved
Version: MP-MU44-3.2_2022V1.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MP-MU44-3.2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Milestone pro MP-MU44-3.2

  • Page 1 User Manual MP-MU44-3.2 4x4 USB 3.2 Matrix All Rights Reserved Version: MP-MU44-3.2_2022V1.0...
  • Page 2 4x4 USB 3.2 Matrix Preface Read this user manual carefully before using the product. Pictures shown in this manual are for reference only. Different models and specifications are subject to real product. This manual is only for operation instruction, please contact the local distributor for maintenance assistance.
  • Page 3 4x4 USB 3.2 Matrix SAFETY PRECAUTIONS To ensure the best from the product, please read all instructions carefully before using the device. Save this manual for further reference. Unpack the equipment carefully and save the original box and packing material ⚫...
  • Page 4: Table Of Contents

    4x4 USB 3.2 Matrix Table of Contents 1. Product Introduction ....................1 1.1 Features ......................1 1.2 Packing List ....................... 2 1.3 Customer Service ....................2 2. Specification ....................... 3 3. Panel Description ......................4 3.1 Front Panel ......................4 3.2 Rear Panel ......................
  • Page 5: Product Introduction

    4x4 USB 3.2 Matrix 1. Product Introduction Thanks for choosing the MP-MU44-3.2 4x4 USB 3.2 Matrix. The matrix allowing 4 x USB devices to be shared between 4 x host devices, supporting Plug-and-Play. The USB data transfer rate is up to 5Gbps.
  • Page 6: Packing List

    4x4 USB 3.2 Matrix 1.2 Packing List 1x MP-MU44-3.2 ⚫ 2x Mounting Ears with 4 Screws ⚫ 4x Plastic Cushions ⚫ 1x RS232 cable ⚫ 1x IR Receiver ⚫ 1x Remote control ⚫ 1x USB3.2 cable (USB A to USB B, 1m) ⚫...
  • Page 7: Specification

    4x4 USB 3.2 Matrix 2. Specification Input Input (4)USB Input Connector (4)USB-A USB Standard USB3.2 Gen1 Output Output (4)USB Output Connector (4)USB-B USB Standard USB3.2 Gen1 Control Control port (1)IR IN, (1)RS232, (1)TCP/IP Control Connector (1)3.5mm mini jack, (1)3-pin terminal blocks, (1)RJ45 General Bandwidth 5Gbps...
  • Page 8: Panel Description

    4x4 USB 3.2 Matrix 3. Panel Description 3.1 Front Panel ① Power LED: Red and green indicator light, the green light is always on when the machine is powered on, the red light is always on in standby mode, and the indicator light is off when the power is off.
  • Page 9: System Connection

    4x4 USB 3.2 Matrix ④ RS232: 3-pin terminal block to connect a computer to control the matrix by sending RS232 commands. ⑤ TCP/IP: Ethernet port to connect with a computer to control the matrix via GUI. ⑥ DC 24V: DC connector for power adapter connection. 4.
  • Page 10: Ir Remote Control

    4x4 USB 3.2 Matrix 5. IR Remote Control • Press the STANDBY button to enter or exit Standby mode. • Inputs represent the device, and Outputs represent the host.In fact, a device can only be bound to one host, and a host can be bound to multiple devices.
  • Page 11: Gui Control

    4x4 USB 3.2 Matrix 6. GUI Control The MP-MU44-3.2 can be controlled via TCP/IP. The default IP settings are: IP Address:192.168.0.178 Subnet Mask:255.255.255.0 Gateway:192.168.0.1 Please type the IP Address of the control PC in the internet browser, and it will enter the below log-in webpage.
  • Page 12: Control Tab

    4x4 USB 3.2 Matrix 6.1 Control Tab Use the 4x4 button grid on the page to set which inputs are directed to which outputs. For example, clicking the button on the Input 1 row and Output 1 column, directs input 1 to output 1.
  • Page 13: Rs232 Tab

    4x4 USB 3.2 Matrix 6.2 RS232 Tab ASCII or HEX command format can be selected. ⚫ Baud Rate: Supports 9600, 19200, 38400, 57600 or 115200. ⚫ Command Ending: NULL, CR, LF or CR+LF can be chosen. ⚫ Command: Type the command in this box to control the third-party device which is ⚫...
  • Page 14: Interface Tab

    4x4 USB 3.2 Matrix 6.3 Interface Tab ⚫ Modify the HOST names ⚫ Modify the Devices names 6.4 Network Tab Static IP or Dynamic Host Configuration Protocol (DHCP). ⚫ ⚫ Modify the static IP Address, Subnet Mask, and Gateway.
  • Page 15: Access Tab

    4x4 USB 3.2 Matrix 6.5 Access Tab Modify the login password ⚫ ⚫ Choose the firmware upgrade file and click confirm to upgrade the firmware ⚫ Lock or unlock the front panel buttons 6.6 GUI Upgrade Please visit at http://192.168.0.178.100 for GUI online upgrade.
  • Page 16: Rs232 Control

    4x4 USB 3.2 Matrix Select the desired update file and press Apply, it will start upgrading then. 7. RS232 control 7.1 RS232 control software ⚫ Installation: Copy the control software file to the control PC ⚫ Uninstallation: Delete all the control software files in corresponding file path. 7.2 Basic Setting: Connect the Matrix with all input devices and output devices needed, then to connect it with a PC which is installed with RS232 control software.
  • Page 17 4x4 USB 3.2 Matrix Set the parameters (baud rate, data bit, stop bit and parity bit) correctly to ensure reliable RS232 control...
  • Page 18: Rs232 Command

    >SetIP [param1] Set Static IP Address param1 = xxx.xxx.x.xxx >SetTelnetPort [param1] Set Telnet Port [param1] param1 = 1~9999 >SetTelnet [param1] Set Telnet Port On Or Off param1 = On, Off >GetIP Get IP <MP-MU44-3.2 >GetStatus >GetStatus <FW Version: V1.0.0 <USB...
  • Page 19 4x4 USB 3.2 Matrix DEVICE 1 HOST <Preset 1 DEVICE 1 HOST <Preset 2 DEVICE 1 HOST <Preset 3 DEVICE 1 HOST <Preset 4 DEVICE 1 HOST <Preset 5 DEVICE 1 HOST <Preset 6 DEVICE 1 HOST <Key On <RS232Baud: 9600 <Telnet On <TelnetPort: 4001 <DHCP Off...
  • Page 20: Panel Drawing

    4x4 USB 3.2 Matrix 4001 >SetTelnet >SetTelnet 0n/0ff <SetTelnet On <SetTelnet Off <SetDHCP Off >SetIP >SetIP <SetIP: 192.168.0.178 192.168.0.178 <RecallPreset 1 >RecallPreset >RecallPreset 01 DEVICE 1 2 3 4 HOST 1 1 1 1 <SavePreset 1 >SavePreset >SavePreset 01 DEVICE 1 2 3 4 HOST 1 2 3 4 >GetIP...

Table of Contents