Page 1
User Manual MPX1616-NT Modular Matrix Switcher 16x16 All Rights Reserved Version: MPX1616-NT_2016V1.0...
Page 2
Modular Matrix Switcher 16x16 Preface Read this user manual carefully before using this product. Pictures shown in this manual is for reference only, different model and specifications are subject to real product. This manual is only for operation instruction only, not for any maintenance usage. Trademarks Product model, and logo are trademarks.
Page 3
Modular Matrix Switcher 16x16 SAFETY PRECAUTIONS To insure the best from the product, please read all instructions carefully before using the device. Save this manual for further reference. ⚫ Unpack the equipment carefully and save the original box and packing material for possible future shipment ⚫...
4.3.2. RS232 Communication Commands ........... 10 4.4. TCP/IP Control (Optional) ................15 4.4.1. Control Modes ................... 15 4.4.2. Control MPX1616-NT via TCP/IP communication software ....16 4.4.3. TCP/IP Configuration ................. 17 5. Specification ......................18 5.1. Main Unit ..................... 18 5.2.
It has 1 RS232 port and 1 optional TCP/IP port for convenient control from third-party. With its flexible design, MPX1616-NT can be used for different project and tend to be an all-in-one solution. It is the combo solution for multimedia conference rooms, control rooms, broadcasting rooms, shopping center etc.
Modular Matrix Switcher 16x16 1.2.1. Modular Matrix Switcher signal card (changeable cards) MPX1616-NT supports multiple signal cards as listed in the following charts: Spec Inputs Signal Format Models 4I-VA VGA& analog audio Input Cards 4I-UH HDMI& analog Audio 4I-BT HDBT, RS232, Audio...
Modular Matrix Switcher 16x16 2. Panel Description 2.1. MPX1616-NT 2.1.1. Front Panel ① ③ ④ ⑥ MPX1616-NT INPUTS MENU SYSTEM MONITOR Undo Enter Through OUTPUTS ② ⑤ Figure 2- 1 Front Panel Name Description IR sensor, receive IR signal sent from IR remote ①...
Note: There are only 4 input and 4 output slots for MPX1616-NT, which enables only 4 input cards and 4 output cards to be installed on MPX1616-NT. The input/output cards can be changed based on your requests and supports hot plug and play.
Modular Matrix Switcher 16x16 can pass to output device through any kinds of output cards. VGA 1 VGA 2 VGA 3 VGA 4 2.2.2. 4I-UH & 4O-UH 4K HDMI signal card. (Please check the specification from 5.2.2) Support HDMI 1.4a& HDCP 1.4 compliance; Compatible with DVI signal; Support high- definition HDMI source up to 4kx2k, 1080p 3D compliance;...
Page 11
Modular Matrix Switcher 16x16 HDBT 1 HDBT 2 HDBT 3 HDBT 4 Audio 1 Audio 2 Audio 3 Audio 4 Note: When matching with output cards that do not support 4kx2k, adjust the input resolution to 1080p to enable reliable output. 4O-BT: output card, maximum output four HDBT signal, output signals from 4I-BT, or other kinds of input cards, need to work with HDBT receivers.
Modular Matrix Switcher 16x16 3. System Connection 3.1. Usage Precautions 1) System should be installed in a clean environment and has a prop temperature and humidity. 2) All of the power switches, plugs, sockets and power cords should be insulated and safe.
Modular Matrix Switcher 16x16 4. Control Operations 4.1. Front Panel Button control Users can control MPX1616-NT rapidly and directly with its front panel buttons. To switch AV signal, please operate the buttons under the following format: Format: “Input Channel” + “AV” +“Output Channel”+“Enter”...
4.3. RS232 Control 4.3.1. Connection of RS232 Communication Port Except the front control panel and IR remote, MPX1616-NT can be controlled by far- end control system or through the Ethernet control via the RS-232 communication port. This RS-232 communication port is a female 9- D connector. The definition of its pin...
Unused Unused Unused Unused When MPX1616-NT connects to the RS232 port of a computer with control software, users can control it by that computer. To control the switcher, users need to use RS232 control software. 4.3.2. RS232 Communication Commands With this command system, users are able to control and operate the MPX1616-NT with RS232 software remotely.
Page 16
Modular Matrix Switcher 16x16 Communication protocol: Baud rate: 9600; Data bit: 8; Stop bit: 1; Parity bit: none. Command Description Feedback MPX1616-NT /*Type; Inquire the models information. System Locked! /%Lock; Lock front panel buttons. System Unlock! /%Unlock; Unlock front panel buttons.
Page 17
Modular Matrix Switcher 16x16 Recall From F8 V: 01->001 Recall[Y]. Recall the preset command [Y]. A: 01->001 … … Clear F8 Clear[Y]. Clear the preset command [Y]. PWON PWON. Work normally. PWOFF PWOFF. Enter in standby mode. HDCPON HDCPON. Turn on the HDCP output. HDCPOFF HDCPOFF.
Page 18
Modular Matrix Switcher 16x16 straight through: 1->1, 2->2,…; saved operation status will remain the same. 4I-VA USER/I/[x]:0648%; Switch on audio of input [x] 0648% USER/I/[x]:0649%; Switch off audio of input [x] 0649% USER/I/[x]:0684%; Set the color space to YCBCR 0684% USER/I/[x]:0685%;...
Page 19
Modular Matrix Switcher 16x16 audio) or 1 (analog audio) Examples: 1、 Transfer signals from an input channel to all output channels: [x]All. Example: Send “3All.” to transfer signals from the input 3 to all output channels. 2、 Transfer all input signals to corresponding output channels respectively: All#. Example: If this command is carried out, the status of matrix will be: 1->1, 2->2, 3->3, 4->4……...
⚫ Controlled by PC(s) in LAN The MPX1616-NT can be connected with a router to make up a LAN with the PC(s), this make it able to be controlled in a LAN. When control, just make sure the MPX1616- NT’s network segment is the same with the router.
Step3. Set the MPX1616-NT’s network segment to the same as the router. Step4. Set the PC’s network segment to the original one. Step5. Connect the MPX1616-NT and PC(s) to the router. In the same LAN, each PC is able to control the MPX1616-NT asynchronously.
Modular Matrix Switcher 16x16 2) After connect successfully, we can enter commands to control the MPX1616-NT, as below: Enter your command here. Commands are the same with RS232 commands listed in 4.3.2 RS232 Communication Commands Here you will receive the feedback when a command is sent.
Modular Matrix Switcher 16x16 5. Specification 5.1. Main Unit Control parts Serial control RS-232, 9- female 2 = TX, 3 = RX, 5 = Configurations port D connector Front panel Installation Rack Mountable Buttons control Options TCP/IP control General Power 100VAC ~ 240VAC, Power Supply 84W (Max)
Modular Matrix Switcher 16x16 6. Troubleshooting & Maintenance Problems Causes Solutions Bad quality of the Try another high quality connecting cable cable Output image with ghost Impropriate image setting Adjust corresponding of the displayer image settings Output image with color Reconnect the displayer losing or no video signal Fail connection...
Page 27
Modular Matrix Switcher 16x16 Static becomes stronger Check the grounding and when connecting the Bad grounding make sure it is connected video connectors well. Wrong RS232 Type in correct RS232 communication communication Cannot control the device parameters parameters. by control device (e.g. a Send it to authorized PC) through RS232 port Broken RS232 port...
Modular Matrix Switcher 16x16 7. After-sales Service If there appear some problems when running MPX1616-NT, please check and deal with the problems referring to this user manual. Any transport costs are borne by the users during the warranty. 1) Product Limited Warranty: We warrant that our products will be free from defects in materials and workmanship for three years, which starts from the first day the product leaves warehouse (check the SN mark on the product).
Need help?
Do you have a question about the MPX1616-NT and is the answer not in the manual?
Questions and answers