SCP-PCS822-021-03H
S
PECIFICATIONS
Table 2
lists the specifications on the PCS-822.
Specification Type
Power
Environmental
Compliance
Physical
12

Table 2. Specifications

Item
Input Voltage Range
Operating Elevation
Operating Temperature
Operating Humidity
NEBS
GR-63-CORE
GR-487-CORE
GR-1089-CORE
Human Safety
FCC
Height
Width
Depth
Weight
Value
–42 Vdc to –56 Vdc
–200 ft. to 13,000 ft.
–60 m to 4,000 m
–40° F to +150° F
–40° C to +65° C
5% to 95% (noncondensing)
SR-3580 Level 3
Equipment is compliant with the applicable
environmental sections when installed in a
pedestal
Equipment is compliant with the applicable
environmental sections when installed in a
pedestal
Field Shelf and installed equipment comply with
the applicable sections for:
• EMI/EMC for Class B equipment
• Electro-Static Discharge
• Lightning Surge
• Power Cross
UL 1950 for Restricted Access
FCC part 15 class B
33.0 in. (83.8 cm.)
12.5 in. (32.0 cm.)
15.0 in. (38.1 cm.)
60.0 lbs. (27.2 kg.)
ADC Telecommunications, Inc.
January 6, 2003