If the machine is over warranty, please also do not hesitate to contact us. we will assure you of our best service all the time. ◆How to contact us? Phone:(+86) 189 -487-55929 Tel: 0755-86368500 Email: sales@mychway.com This product does not belong to medical,please don’t use for disease treatment! - 2 -...
1. Introduction to Manual 1.1 Purpose This instructions for use manual provides a description of the system components, its controls and displays, instructions for its operation, and other equipment information important to the user Warning: Do Not operate this machine before reading this manual thoroughly. In addition to this manual,additional clinical training may be available by the company or your local distributor.
2.2. Contraindications The SMART HIFU FACE LIFTING system is contraindicated for use in patients with: Open wounds or lesions on the face and/or neck Severe or cystic acne on the face and/or neck 2.3. Precautions The SMART HIFU FACE LIFTING system has not been evaluated for use over various materials.
a location or technique where ultrasound energy can reach the eye Warning: Use this system only if you are trained and qualified to do so. Warning: If any problems occur during system operation, ask immediate action(s): lift the transducer off the patent’s skin, press the STOP button to completely halt system operation.
tissue that can stimulate and renew skin's collagen and thus tighten the skin and remove wrinkles. It successfully achieves a quite good result of skin tightening and face lifting without any help of invasive surgeries. 3.2 System Components and Features 3.2.1 Control Unit &Handpiece A.
3.2.2 Transducers Fig 3.0 transducers The types of transducers reflect variations in frequencies and treatment depths as following shown TRANSDUCER TYPE TREAT FREQUENCY TREAT DEPTH 4 MHz 4.5 mm DS 4 – 4.5 DS 7 – 3.0 7 MHz 3.0 mm DS 10 –...
Do not remove the covers on the control unit or handpiece; the control unit contains hazardous voltages. The system contains no user-serviceable components. If the system requires service, contact mychway, Inc. No modification of this equipment is allowed. The system should not be used near flammable gases or anesthetics. Fire or explosion can result.
The system has no user-serviceable components. Do not attempt to open the control unit enclosure or transducers. Contact mychway, Inc. if service is required. 5. Setting Up for First-Time Use 5.1. Unpacking The control unit and handpiece are shipped together in one container.
Step 2: put ultrasound gel on the window of the transducer Step 3: set energy and length,press start/pause button Result: the system work well if ultrasound gel move even splashing,if not,please contact mychway.,Inc. 6. Treatment Guidelines. 6.1 Install control unit and handpiece with transducer...
ii. Install the probe into the handle iii. You will see the handle screen shows “E” means Energy “L” means length. Set the energy and length according patient feeling. 6.2 Treatment Guideline. Table 2.0 7. Andorid APP The andorid mobile phone or andorid pad need download Caution mobile phone or pad need with bluetooth function 7.1 Connecting Bluetooth...
then the handle screen will show a Bluetooth sign and you phone will change to fig 5.0 Fig 5.0 7.2 Operation on APP Detail Energy, length and treatment areas and lines shown on the app images, just follow the guideline to use this system with recommendation table 2.0 8.
9. Package Listing Main machine 1PCS Focused ultrasonic handle 1PCS Transducer DS-4.5 1PCS Transducer DS-3.0 1PCS Transducer DS-1.5 1PCS Power cord 1PCS 10 Cleaning and Care 10.1. Cleaning the Transducer and Handpiece Note: Transducers are packaged and shipped non-sterile and ready to use. Because the transducer will come in contact with the skin of a patient, the standard practice for cleaning and low level disinfection of transducers between patients is to gently but thoroughly wipe the transducers with a standard 70%...
Page 15
5. Use ultrasonic/ultrasound gel only. Other lubricants or lotions, particularly mineral oil, could eventually damage transducers or cables. 6. Do not use acoustic standoff pads or any objects between the transducer and patient. 7. Apply ultrasound gel only to the window of the transducer and wipe it from the transducer after completing a treatment.